Halogen-Free Screened Marine Power Cable 0.6/1 kV

This 0.6/1 kV halogen-free flexible marine power cable incorporates an overall tinned copper braid for enhanced electromagnetic compatibility. It delivers dependable power transmission, flexible installation and low-smoke fire performance for shipboard machinery and electrically sensitive marine systems.

Key Highlights

Halogen-free screened marine power cable · 0.6/1 kV rated · Overall tinned copper braid · Good EMC performance · 4000 V test voltage · Flexible Class 5 conductors · SHF1 marine outer sheath · Low smoke density · No flame propagation · Flame-retardant and self-extinguishing · Non-corrosive combustion gases · Wide conductor-size range · RoHS-compatible

Designed for protected marine power circuits where electromagnetic interference must be controlled.

Typical applications include:

  • EMC-sensitive marine power systems
  • Shipboard motors and auxiliary machinery
  • Engine-room equipment
  • Pumps, fans and ventilation systems
  • Power and control cabinets
  • Frequency-controlled equipment
  • Navigation and deck machinery
  • Protected power wiring above or below deck

The cable should not remain in permanent contact with oils or fuels unless an appropriate oil-resistant sheath has been selected.

Conductor: Fine-stranded tinned copper, Class 5 according to IEC 60228/VDE 0295

Core insulation: Special halogen-free compound

Core identification: Black cores with consecutive numbers according to EN 50334

Protective conductor: Green-yellow earth conductor included from three-core configurations

Core arrangement: Cores stranded together in layers

Overall screen: Tinned copper braid

Outer sheath: Halogen-free SHF1 compound according to IEC 60092-360

Standard sheath color: Black, similar to RAL 9005

Optional construction: Bare copper conductors, alternative core identification and customized sheath colors available on request

Nominal voltage: U₀/U 0.6/1 kV

Test voltage:

  • Core-to-core: 4000 V
  • Core-to-screen: 4000 V

Minimum bending radius:

  • Fixed installation: 4 × cable diameter
  • Flexible application: 6 × cable diameter

Temperature range:

  • Fixed installation: −40°C to +90°C
  • Flexible application: −30°C to +90°C

Conductor class: IEC 60228 Class 5

Halogen-free performance: IEC 60754-1

Flame propagation: IEC 60332-3-22, Category A

Flame retardancy: IEC 60332-1-2

Corrosiveness of combustion gases: IEC 60754-2

Smoke density: IEC 61034

Outer sheath standard: IEC 60092-360 SHF1

Environmental compliance: RoHS-compatible materials

Marine approval, PFAS-free formulation and project-specific certification requirements are subject to confirmation.

Representative standard configurations:

Number of Cores × Cross-Section Approx. Outer Diameter Copper Weight Approx. Cable Weight
2 × 1.50 mm² 9.4 mm 55.0 kg/km 123 kg/km
18 × 1.50 mm² 20.4 mm 384.8 kg/km 654 kg/km
2 × 2.50 mm² 10.2 mm 77.1 kg/km 155 kg/km
18 × 2.50 mm² 22.6 mm 572.7 kg/km 865 kg/km
2 × 4.00 mm² 12.6 mm 131.3 kg/km 238 kg/km
7 × 4.00 mm² 17.9 mm 379.7 kg/km 566 kg/km
2 × 6.00 mm² 13.8 mm 175.0 kg/km 303 kg/km
7 × 6.00 mm² 19.6 mm 527.5 kg/km 723 kg/km
5 × 16.00 mm² 25.6 mm 938.8 kg/km 1231 kg/km
5 × 25.00 mm² 30.8 mm 1400.7 kg/km 1805 kg/km
4 × 35.00 mm² 31.3 mm 1546.6 kg/km 1978 kg/km
4 × 50.00 mm² 35.2 mm 2149.1 kg/km 2678 kg/km

Available conductor sizes range from approximately 1.50 mm² to 50.00 mm². Core counts vary according to conductor cross-section. Copper figures include the conductors and overall copper screen. Outer diameters are subject to a tolerance of approximately ±10%.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top