cULus Shielded High-Dynamic Twisted Pair Data Cable 300 V
This high-dynamic twisted-pair data cable combines Class 6 copper conductors, halogen-free core insulation, an overall tinned copper braid and a matte PUR sheath. It provides reliable data transmission, reduced crosstalk and EMC protection for long-travel drag chains with more than 10 million bending cycles.
Key Highlights
More than 10 million bending cycles · Twisted-pair construction · Overall tinned copper braid · Good EMC performance · Reduced crosstalk · 300 V cULus reference approval · AWM Style 21209 · Continuous long-travel operation · Halogen-free insulation · Flame-retardant and self-extinguishing · Matte PUR sheath · Oil resistant · PFAS-free · RoHS compliant
- Application
- Construction
- Technical Data
- Dimensions
- Packaging
Designed for continuously moving and interference-sensitive signal connections in:
- High-speed industrial automation
- Long-travel drag chains
- Robotic systems
- Material-handling equipment
- Packaging and production machinery
- Machine tools
- Automotive manufacturing systems
- Encoder and sensor connections
- Analogue and digital signal circuits
- Automated warehouse equipment
The twisted-pair structure improves transmission performance and crosstalk attenuation. The overall tinned copper braid protects sensitive signals from electromagnetic interference generated by motors, drives and switching equipment.
- Conductor: Flexible bare copper strands with reference to IEC 60228 and VDE 0295 Class 6
- Core insulation: Halogen-free special polymer compound
- Core identification: Color-coded with reference to DIN 47100
- Pair arrangement: Insulated cores twisted into pairs
- Cable assembly: Pairs stranded in specially adjusted layers
- Intermediate protection: Non-woven tape over each layer
- Overall screen: Tinned copper wire braid
- Outer wrapping: Non-woven tape
- Outer sheath: PUR
- Sheath surface: Matte
- Standard sheath color: Black, similar to RAL 9005
- Material characteristics: Halogen-free, PFAS-free and PWIS-uncritical reference construction
- Maximum peak operating voltage: 350 V
- cULus reference voltage: 300 V
- Test voltage, core to core: 2000 V
- Test voltage, core to screen: 2000 V
- Minimum bending radius, fixed installation: 3 × cable outer diameter
- Minimum bending radius, flexible application: 7.5 × cable outer diameter
- Reference bending endurance: More than 10 million bending cycles
- Fixed installation temperature range: −50°C to +90°C
- Flexible application temperature range: −40°C to +90°C
- cULus reference temperature rating: Up to +90°C
- Halogen-free performance: IEC 60754-1 and VDE 0482-754-1 reference
- Flame performance: Flame-retardant and self-extinguishing according to IEC 60332-1-2 and VDE 0482-332-1-2 reference tests
- North American flame tests: cULus FT1 and FT2 reference performance
- Oil resistance: Very good, TMPU according to EN 50363-10-2 and VDE 0207-363-10-2
- Chemical resistance: Good resistance to acids, alkaline solutions, solvents and hydraulic fluids
- Continuous-flex performance: Very good
- Sunlight resistance: HD 605 reference performance
- Ozone resistance: DIN EN 50396 reference performance
- Saltwater resistance: UL 1309 reference performance
- Reference approval and marking: cULus AWM Style 21209, 300 V, 90°C
- Environmental compliance: RoHS-compliant and PFAS-free reference construction
- Reference conformity: CE
| Pair Configuration | Largest Single-Wire Ø (mm) | Approx. Outer Ø ±10% (mm) | Copper Weight (kg/km) | Approx. Cable Weight (kg/km) |
| 2 × 2 × 0.14 mm² | 0.11 | 4.9 | 19.1 | 31 |
| 3 × 2 × 0.14 mm² | 0.11 | 5.4 | 21.8 | 36 |
| 4 × 2 × 0.14 mm² | 0.11 | 5.8 | 26.3 | 40 |
| 2 × 2 × 0.25 mm² | 0.11 | 5.4 | 23.6 | 37 |
| 3 × 2 × 0.25 mm² | 0.11 | 6.0 | 30.4 | 47 |
| 4 × 2 × 0.25 mm² | 0.11 | 6.7 | 36.9 | 55 |
| 6 × 2 × 0.25 mm² | 0.11 | 7.2 | 48.5 | 71 |
| 7 × 2 × 0.25 mm² | 0.11 | 7.7 | 55.1 | 80 |
| 10 × 2 × 0.25 mm² | 0.11 | 8.6 | 74.2 | 99 |
| 2 × 2 × 0.34 mm² | 0.11 | 5.7 | 27.3 | 42 |
| 3 × 2 × 0.34 mm² | 0.11 | 6.2 | 35.9 | 52 |
| 4 × 2 × 0.34 mm² | 0.11 | 7.2 | 46.1 | 64 |
| 7 × 2 × 0.34 mm² | 0.11 | 8.3 | 70.0 | 97 |
| 2 × 2 × 0.50 mm² | 0.16 | 6.7 | 36.9 | 59 |
| 3 × 2 × 0.50 mm² | 0.16 | 7.4 | 50.1 | 82 |
| 4 × 2 × 0.50 mm² | 0.16 | 8.4 | 62.2 | 93 |
| 5 × 2 × 0.50 mm² | 0.16 | 9.1 | 74.3 | 114 |
| 6 × 2 × 0.50 mm² | 0.16 | 9.4 | 86.6 | 128 |
| 8 × 2 × 0.50 mm² | 0.16 | 11.7 | 131.1 | 198 |
| 10 × 2 × 0.50 mm² | 0.16 | 11.6 | 150.3 | 203 |
| 2 × 2 × 0.75 mm² | 0.16 | 7.3 | 48.6 | 70 |
| 3 × 2 × 0.75 mm² | 0.16 | 8.1 | 66.9 | 90 |
| 4 × 2 × 0.75 mm² | 0.16 | 9.2 | 86.6 | 113 |
| 6 × 2 × 0.75 mm² | 0.16 | 10.5 | 134.1 | 178 |
| 4 × 2 × 1.00 mm² | 0.16 | 9.7 | 106.0 | 129 |
| 6 × 2 × 1.00 mm² | 0.16 | 11.4 | 169.2 | 221 |
| 6 × 2 × 1.50 mm² | 0.16 | 12.8 | 232.5 | 423 |
Other pair counts, conductor sizes, sheath colors and customized dimensions are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
SEND US YOUR
SPECIFICATION
Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.
Your information is used only to prepare your quotation and is never shared with third parties.
RELATED SERIES
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen jacket with numbered cores for fast identification during panel wiring and maintenance.
View Product →
Halogen-Free Single Conductor Wiring Cable 450/750 V
Extended temperature range for control cabinet and switchgear wiring where flame behaviour is critical.
View Product →
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen construction with braid screening for reliable EMC performance in dense cabinets.
View Product →
Halogen-Free Single Conductor Wiring Cable 600 V UL
Flame retardant and UL recognised for North American panel builds and export-bound equipment.
View Product →