Low-Capacitance Combined Shielded PUR Servo Motor Cable 0.6/1 kV

This combined servo motor cable integrates 0.6/1 kV motor power cores with individually screened control or brake pairs. Its low-capacitance insulation, overall tinned-copper braid and flexible PUR sheath provide reliable power transmission and EMC performance in moving servo-drive applications.

Key Highlights

Combined motor power and control cable · 0.6/1 kV power cores · Individually screened control pairs · Overall tinned-copper braid · Low-capacitance construction · Very good EMC performance · Flexible cable-track use · Halogen-free · Very good oil resistance · Low-temperature flexibility · Long service life · Weather resistant · PFAS-free option · PWIS-uncritical option

Recommended for:

  • Servo motor power and control connections
  • Motor power and brake-signal circuits
  • Variable-frequency drives
  • Machine tools and production machinery
  • Industrial robots and automation equipment
  • Flexible cable tracks
  • Applications requiring power and control functions in one cable
  • Installations requiring individually screened control pairs and an overall screen

Conductor: Class 6 flexible bare copper strands according to IEC 60228 and VDE 0295
Core insulation: Halogen-free special low-capacitance polymer compound
Power-core identification: Numbered or function-marked black cores with green/yellow protective conductor
Control-core identification: Numbered or color-coded according to the required drive system
Control-core arrangement: Twisted into pairs
Control-pair wrapping: Aluminium foil
Control-pair screen: Tinned-copper braid
Control-pair outer wrapping: Foil
Cable arrangement: Screened control pairs and power cores stranded together with fillers
Overall wrapping: Nonwoven tape
Overall screen: Tinned-copper braid
Screen wrapping: Nonwoven tape
Outer sheath: Matte PUR/TMPU according to EN 50363-10-2 and VDE 0207-363-10-2
Standard sheath color: Orange, similar to RAL 2003
Optional versions: Customized power sizes, control-pair combinations and core identification available on request

Nominal voltage of power cores: U₀/U 0.6/1 kV
Maximum operating voltage of control cores: 350 V
cULus voltage reference: 1000 V
Testing voltage for power cores, core to core: 4000 V
Testing voltage for power cores, core to screen: 4000 V
Testing voltage for control cores, core to core: 2000 V
Testing voltage for control cores, core to screen: 2000 V
Minimum bending radius, fixed installation: 5 × cable outer diameter
Minimum bending radius, flexible application: 10 × cable outer diameter
Fixed temperature range: −50°C to +90°C
Flexible temperature range: −40°C to +90°C
cULus temperature reference: Up to +80°C
Halogen-free performance: IEC 60754-1 and VDE 0482-754-1
Flame performance: IEC 60332-1-2 and VDE 0482-332-1-2
Oil resistance: Very good
Chemical resistance: Good resistance to acids, alkalis, solvents and hydraulic fluids
Weather resistance: Very good
Approval options: cULus, FT1, FT2, RoHS, PFAS-free and PWIS-uncritical, subject to HULK product certification

Control Arrangement Configuration Approx. Outer Ø (mm) Copper Weight (kg/km) Approx. Cable Weight (kg/km)
Two Control Pairs 4 × 1.50 mm² + 2 × (2 × 0.75 mm²) 11.4 ± 0.8 166.5 211
Two Control Pairs 4 × 2.50 mm² + 2 × (2 × 1.00 mm²) 13.1 ± 0.8 To be confirmed: 195.5 webpage / 225.2 PDF To be confirmed: 245 webpage / 276 PDF
Two Control Pairs 4 × 4.00 mm² + (2 × 1.00 mm²) + (2 × 1.50 mm²) 15.0 ± 0.8 303.2 373
Two Control Pairs 4 × 6.00 mm² + (2 × 1.00 mm²) + (2 × 1.50 mm²) 17.1 ± 0.8 422.9 497
Two Control Pairs 4 × 10.0 mm² + (2 × 1.00 mm²) + (2 × 1.50 mm²) 19.3 ± 0.8 581.3 692
Two Control Pairs 4 × 16.0 mm² + 2 × (2 × 1.50 mm²) 22.9 ± 0.8 860.1 1012
Two Control Pairs 4 × 25.0 mm² + 2 × (2 × 1.50 mm²) 28.2 ± 0.8 1240.8 1447
One Control Pair 4 × 1.00 mm² + (2 × 0.50 mm²) 9.0 ± 0.8 88.2 120
One Control Pair 4 × 1.50 mm² + (2 × 1.50 mm²) 10.7 ± 0.8 150.5 189
One Control Pair 4 × 1.50 mm² + (2 × 0.50 mm²) 9.5 ± 0.8 108.0 142
One Control Pair 4 × 2.50 mm² + (2 × 1.50 mm²) 12.2 ± 0.8 195.5 244
One Control Pair 4 × 4.00 mm² + (2 × 1.50 mm²) 13.6 ± 0.8 262.1 317
One Control Pair 4 × 6.00 mm² + (2 × 1.50 mm²) 16.3 ± 0.8 376.8 450
One Control Pair 4 × 10.0 mm² + (2 × 1.50 mm²) 18.5 ± 0.8 544.0 657
One Control Pair 4 × 16.0 mm² + (2 × 1.50 mm²) 22.1 ± 0.8 797.1 946
One Control Pair 4 × 25.0 mm² + (2 × 1.50 mm²) 26.2 ± 0.8 1170.6 1354

Other power-core sizes, control-pair combinations and customized dimensions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top