Torsion-Resistant USB 3.0 Cable for Robotics
A shielded USB 3.0 (USB 3.2 Gen 1×1) cable design for robot-mounted cameras and other devices that move with an articulated arm. Specify the cable around the wrist rotation, available routing space, and distance to the host computer.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
Use this design for machine vision cameras on robot wrists, movable inspection heads, and USB devices on rotating end effectors. Where the cable bends and twists in the same section, check the free length between clamps and the tightest bend through the robot’s full travel. Explore USB cables for robotics applications for other interface and routing requirements.
| Component | Reference design |
| Conductors | Fine-stranded conductors with silver-plated and tinned copper elements |
| Insulation | Special polymer |
| Core layout | Three screened twisted data pairs and two power conductors |
| Wrapping and overall shield | Mesh and nonwoven tapes with a tinned copper braid |
| Outer jacket | Black polyurethane (PUR) |
| Parameter | Reference value |
| Transmission length | Up to 3 m |
| Cable peak operating voltage | 350 V max. |
| Dielectric test voltage | 2,000 V conductor-to-conductor and conductor-to-shield |
| Minimum bend radius | 5 × cable OD fixed, 10 × OD flexible, 15 × OD continuous flex |
| Torsion angle | Up to ±360° per metre |
| Cable temperature range | −50 to +90 °C fixed, −40 to +90 °C moving |
| Flame test reference | IEC 60332-1-2 / EN 60332-1-2 |
| Jacket compound reference | TMPU per EN 50363-10-2 |
| Data pairs | Power conductors | Nominal OD (±10%) | Copper figure | Approx. cable weight | Max. conductor resistance at 20 °C |
| 3 screened pairs, 28 AWG | 2 × 26 AWG | 6.4 mm | 28.1 kg/km | 50 kg/km | 223 Ω/km data, 140 Ω/km power |
| 3 screened pairs, 26 AWG | 2 × 24 AWG | 8.0 mm | 38.9 kg/km | 73 kg/km | 130 Ω/km data, 83.3 Ω/km power |
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity