High-Flex Screened CAN Bus Reeling Cable

A screened CAN bus cable design for repeated winding and unwinding on industrial reels. The two-pair reference construction combines an overall tinned copper screen with a supporting braid between two PUR sheath layers.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

This design suits CAN bus links to moving industrial equipment that pays out cable from a drum and takes it up during return travel. The winding radius and the radius over guide pulleys have separate limits, which matter when a route includes both. See cables for reeling applications for related reel-fed cable constructions.

Component Reference design
Conductors Stranded bare copper, 0.50 mm² per conductor
Core insulation Polyethylene (PE)
Core identification DIN 47100 color code reference
Pair layout Two twisted pairs laid together
Core wrap Nonwoven tape
Overall screen Tinned copper braid
Sheath construction PUR inner layer, supporting braid, and PUR outer layer
Jacket color Black, similar to RAL 9005
Parameter Reference value
Installation duty Fixed routing, repeated winding, and pulley-guided movement
Characteristic impedance 120 Ω nominal, 95–140 Ω reference range
Peak operating voltage of bulk cable 350 V max.
Dielectric test voltage 1,500 V core-to-core, 1,200 V core-to-screen
Minimum bend radius, fixed installation 5 × cable OD
Minimum bend radius, repeated winding 7.5 × cable OD
Minimum bend radius, pulley-guided movement 10 × cable OD
Temperature range −40 to +90 °C fixed and moving, per the current SAB product page
Halogen acid gas test reference IEC 60754-1 / VDE 0482-754-1
Oil resistance reference TMPU per EN 50363-10-2 / VDE 0207-363-10-2
Max. conductor resistance at 20 °C 39 Ω/km, VDE 0812 reference
Max. tensile force 200 N, per SAB
Reference assembly options M12 or RJ45, with the pin assignment matched to the CAN equipment
SAB reference item Conductor layout Nominal OD (±10%) Copper figure Approx. cable weight
L06899005 2 pairs, 2 × 2 × 0.50 mm² 12.8 mm 48.8 kg/km 175 kg/km

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top