Flexible PVC PROFIBUS PA Cable

A shielded PVC PROFIBUS PA cable design for fixed and general flexible wiring in process automation. The reference range includes several single-pair conductor sizes and two-pair Type B layouts for matching existing fieldbus wiring.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

This design suits instrument connections between field junction boxes and devices such as transmitters and valve positioners. The PVC jacket is suited to fixed routes and sections that flex during installation or servicing. Compare fixed and moving cable designs in the PROFIBUS PA cable range.

Component Reference design
Conductors Stranded bare copper
Core insulation 2YI1 polyethylene (PE)
Core identification Red and green for single-pair PA layouts. DIN 47100 colors for two-pair Type B layouts.
Core wrap PET polyester film
Overall screen Tinned copper braid
Outer jacket TM2 PVC per EN 50363-4-1
Parameter Reference value
Installation duty Fixed and general flexible routing
PA characteristic impedance 100 Ω ±20%
Type B characteristic impedance 100–130 Ω above 100 kHz
Peak operating voltage of bulk cable 350 V max.
Dielectric test voltage 1,500 V core-to-core, 1,200 V core-to-screen
Minimum bend radius 7.5 × cable OD
Temperature range −30 to +70 °C fixed, −5 to +70 °C flexible
Oil resistance test SAB internal test method
Conductor layout Jacket color Nominal OD (±10%) Copper figure Approx. cable weight
1 pair, 2 × 0.22 mm² Red lilac, RAL 4001 4.4 mm 14.7 kg/km 26 kg/km
2 pairs, 2 × 2 × 0.22 mm² Red lilac, RAL 4001 6.2 mm 22.4 kg/km 45 kg/km
1 pair, 2 × 0.25 mm² Red lilac, RAL 4001 4.9 mm 15.4 kg/km 30 kg/km
2 pairs, 2 × 2 × 0.25 mm² Red lilac, RAL 4001 6.7 mm 26.5 kg/km 52 kg/km
PA variant, 2 × 0.82 mm² Blue, RAL 5015 7.3 mm 38.1 kg/km 68 kg/km
PA variant, 2 × 0.82 mm² Black, RAL 9005 7.3 mm 38.1 kg/km 68 kg/km

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top