Robot Hybrid Power and Signal Cable 350 V – TPE/PUR
This flexible robot hybrid cable combines power, control and paired signal conductors within one compact cable. Special-polymer and TPE insulation, multiple conductor sizes and a durable PUR/TMPU outer sheath support reliable transmission in moving robotic equipment.
Key Highlights
Combined power, control and signal transmission · Five signal pairs · Maximum 350 V · Special-polymer/TPE insulation · PUR/TMPU sheath · Compact hybrid construction · Flexible down to -40°C · RoHS compliant
- Application
- Construction
- Technical Data
- Dimensions
- Packaging
Designed for industrial robots and automated machines that require power supply, control functions and signal transmission through one cable. The integrated construction helps reduce the number of separate cables required inside robot arms and dress packages.
- Conductor: Bare copper strands according to IEC 60228
- Insulation: Special polymer and TPE
- Cable configuration: 4 × 1.0 mm² + 5 × 2 × 0.25 mm² + 1 × 1.0 mm²
- Signal elements: Five conductor pairs, each containing 2 × 0.25 mm²
- Core identification: With reference to DIN 47100
- Additional core colours: Black, blue, red, brown and green-yellow
- Outer sheath: PUR/TMPU according to EN 50363-10-2 and VDE 0207-363-10-2
- Sheath colour: Red-lilac, similar to RAL 4001
- Maximum nominal voltage: 350 V
- Core-to-core testing voltage: 1700 V
- Core-to-screen testing voltage: 1000 V
- Temperature range for flexible applications: -40°C to +70°C
- Recommended minimum bending radius: 10 × cable diameter
- RoHS compliant
| Cable Configuration | Approx. Outer Diameter |
| 4 × 1.0 mm² + 5 × 2 × 0.25 mm² + 1 × 1.0 mm² | 13.2 mm |
Other power-core sizes, signal-pair combinations, colours and customized dimensions are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
SEND US YOUR
SPECIFICATION
Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.
Your information is used only to prepare your quotation and is never shared with third parties.
RELATED SERIES
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen jacket with numbered cores for fast identification during panel wiring and maintenance.
View Product →
Halogen-Free Single Conductor Wiring Cable 450/750 V
Extended temperature range for control cabinet and switchgear wiring where flame behaviour is critical.
View Product →
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen construction with braid screening for reliable EMC performance in dense cabinets.
View Product →
Halogen-Free Single Conductor Wiring Cable 600 V UL
Flame retardant and UL recognised for North American panel builds and export-bound equipment.
View Product →