PVC Robotic Torsion Cable 300/500 V
This flexible PVC robotic cable is engineered for continuous torsional movement of up to ±270° over a cable length of 0.5 m. Its robust, oil-resistant construction provides reliable power, control and signal transmission in robots, automated machinery and other industrial equipment.
Key Highlights
Torsion angle up to ±270° over 0.5 m · Flexible Class 6 copper conductors · Durable PVC insulation and sheath · Very good oil resistance · Flame-retardant construction · Suitable for continuous robotic movement · Wide selection of conductor sizes · UL and CSA reference approvals · RoHS compliant · PFAS-free
- Application
- Construction
- Technical Data
- Dimensions
- Packaging
Designed for robotic and automated equipment requiring repeated torsional movement.
Typical applications include:
- Industrial robots and robotic arms
- Packaging and processing machinery
- Woodworking and textile machinery
- Welding and cutting equipment
- Automotive production and assembly lines
- Electrical drive and control systems
- Measurement and instrumentation equipment
- Industrial plants and machine tools
- Conductor, 0.14–0.34 mm²: extra-fine stranded bare copper
- Conductor, from 0.50 mm²: flexible Class 6 stranded bare copper according to IEC 60228 and VDE 0295
- Core insulation: PVC TI2 according to EN 50363-3 and VDE 0207-363-3
- Core identification, 0.14–0.34 mm²: US 2 colour code
- Core identification, from 0.50 mm²: according to EN 50334 and VDE 0293-334
- Protective conductor: green/yellow from three cores
- Core assembly: specially designed layered stranding with netting tape over each layer
- Outer wrapping: additional non-woven tape
- Outer sheath: oil-resistant PVC TM5 according to EN 50363-4-1 and VDE 0207-363-4-1
- Standard sheath colour: black, similar to RAL 9005
- Peak operating voltage, 0.14–0.34 mm²: maximum 350 V
- Nominal voltage, from 0.50 mm²: U₀/U 300/500 V
- UL voltage rating, 0.14–0.34 mm²: 300 V
- UL/CSA voltage rating, from 0.50 mm²: 600 V
- Test voltage, 0.14–0.34 mm²: 1,500 V core-to-core
- Test voltage, from 0.50 mm²: 2,000 V core-to-core
- Maximum torsion angle: ±270° over 0.5 m
- Minimum bending radius during continuous movement: 12 × cable diameter
- Minimum bending radius from 34 cores: 20 × cable diameter
- Fixed installation temperature: -40°C to +70°C
- Flexible application temperature: +5°C to +70°C
- UL temperature rating, 0.14–0.34 mm²: up to +80°C
- UL/CSA temperature rating, from 0.50 mm²: up to +90°C
- Flame retardancy, 0.14–0.34 mm²: IEC 60332-1-2 and UL VW-1
- Flame retardancy, from 0.50 mm²: IEC 60332-1-2, VDE 0482-332-1-2, UL VW-1, CSA FT1 and FT2
- Oil resistance: PVC TM5 according to EN 50363-4-1 and VDE 0207-363-4-1
- Reference oil performance: UL 758 Oil Rating 60°C and CSA Fuel Oil requirements
- Continuous flexibility: very good
- Reference compliance: UL recognized, CSA approved, RoHS compliant and PFAS-free
| Core Configuration | Largest Single Wire Ø (mm) | Approx. Outer Ø ±10% (mm) | Copper Weight (kg/km) | Approx. Cable Weight (kg/km) |
| 3 × 0.14 mm² | 0.11 | 5.2 | 4.0 | 31 |
| 4 × 0.14 mm² | 0.11 | 5.6 | 5.4 | 36 |
| 3 × 0.25 mm² | 0.11 | 5.4 | 7.2 | 37 |
| 4 × 0.25 mm² | 0.11 | 5.9 | 9.6 | 43 |
| 7 × 0.25 mm² | 0.11 | 7.3 | 16.8 | 67 |
| 25 × 0.25 mm² | 0.11 | 11.2 | 60.0 | 173 |
| 2 × 0.34 mm² | 0.11 | 5.3 | 6.5 | 36 |
| 25 × 0.50 mm² | 0.16 | 14.8 | 120.0 | 332 |
| 4 × 0.75 mm² | 0.16 | 7.4 | 28.8 | 75 |
| 7 × 0.75 mm² | 0.16 | 9.6 | 67.2 | 134 |
| 14 × 0.75 mm² | 0.16 | 12.5 | 100.8 | 225 |
| 2 × 1.00 mm² | 0.16 | 6.8 | 19.2 | 59 |
| 3 × 1.00 mm² | 0.16 | 6.9 | 28.8 | 71 |
| 4 × 1.00 mm² | 0.16 | 7.8 | 38.4 | 90 |
| 12 × 1.00 mm² | 0.16 | 12.4 | 115.2 | 234 |
| 18 × 1.00 mm² | 0.16 | 14.4 | 172.8 | 334 |
| 25 × 1.00 mm² | 0.16 | 16.9 | 240.0 | 468 |
| 34 × 1.00 mm² | 0.16 | 20.1 | 326.4 | 624 |
| 41 × 1.00 mm² | 0.16 | 21.4 | 393.6 | 732 |
| 18 × 1.50 mm² | 0.16 | 16.5 | 259.2 | 456 |
| 25 × 1.50 mm² | 0.16 | 18.7 | 360.0 | 630 |
| 3 × 2.50 mm² | 0.16 | 9.8 | 72.0 | 146 |
| 4 × 2.50 mm² | 0.16 | 10.6 | 96.0 | 184 |
| 3 × 4.00 mm² | 0.16 | 12.1 | 115.2 | 225 |
| 3 × 10.00 mm² | 0.21 | 16.8 | 288.0 | Not stated* |
| 3 × 16.00 mm² | 0.21 | 19.7 | 460.8 | 731 |
| 3 × 25.00 mm² | 0.21 | 23.8 | 720.0 | 1,080 |
| 3 × 35.00 mm² | 0.21 | 27.2 | 1,008.0 | 1,470 |
*The reference source does not provide the approximate cable weight for the 3 × 10.00 mm² version. This value must be confirmed by HULK engineering before publication.
Other conductor sizes, core configurations, sheath colours and customized dimensions are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
SEND US YOUR
SPECIFICATION
Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.
Your information is used only to prepare your quotation and is never shared with third parties.
RELATED SERIES
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen jacket with numbered cores for fast identification during panel wiring and maintenance.
View Product →
Halogen-Free Single Conductor Wiring Cable 450/750 V
Extended temperature range for control cabinet and switchgear wiring where flame behaviour is critical.
View Product →
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen construction with braid screening for reliable EMC performance in dense cabinets.
View Product →
Halogen-Free Single Conductor Wiring Cable 600 V UL
Flame retardant and UL recognised for North American panel builds and export-bound equipment.
View Product →