High-Flex Shielded Halogen-Free TPE/PUR Control Cable 300/500 V for Long-Travel Drag Chains

This shielded 300/500 V control cable combines highly flexible Class 6 conductors, TPE insulation, an overall tinned-copper braid and a durable PUR outer sheath. It is designed for continuous movement, long travel and EMC-sensitive industrial applications.

Key Highlights

Continuous-flex shielded control cable · 300/500 V rated · Numbered cores · Overall tinned-copper braid · Improved EMC performance · Halogen-free · Low-temperature flexibility · Travel distances greater than 10 m · Small bending radius · Compact outer diameter · High abrasion resistance · Very good oil resistance · Weather resistant · PFAS-free option · PWIS-uncritical option

Recommended for continuously moving control and power connections in:

  • Automated handling and material-handling systems
  • Industrial robots and production machinery
  • Packaging and woodworking equipment
  • Automotive manufacturing systems
  • High-bay warehouse installations
  • Long-travel drag chains exceeding 10 metres
  • Equipment requiring copper-braid screening for improved EMC performance

Conductor: Class 6 flexible bare copper strands according to IEC 60228 and VDE 0295
Core insulation: TPE
Core identification: Black cores with consecutive white numbers according to EN 50334 and VDE 0293-334
Protective conductor: Green/yellow core included from three-core configurations
Core arrangement: Specially optimized layer construction with nonwoven tape over each layer
Inner sheath: Halogen-free inner sheath compound
Inner wrapping: Nonwoven tape
Overall screen: Tinned-copper braid
Screen wrapping: Nonwoven tape
Outer sheath: Matte PUR/TMPU according to EN 50363-10-2 and VDE 0207-363-10-2
Standard sheath color: Grey, similar to RAL 7000
Optional versions: Alternative conductor sizes, core counts, colors, hybrid constructions and single-core versions available on request

Nominal voltage: U₀/U 300/500 V
Testing voltage, core to core: 2000 V
Testing voltage, core to screen: 2000 V
Minimum bending radius: 7.5 × cable outer diameter in continuous-flex applications
Fixed temperature range: −50°C to +90°C
Flexible temperature range: −40°C to +90°C
Radiation resistance: 1 × 10⁷ cJ/kg
Halogen-free performance: IEC 60754-1 and VDE 0482-754-1
Oil resistance: Very good
Chemical resistance: Good resistance to acids, alkalis, solvents and hydraulic fluids
Continuous-flex performance: Very good
Weather resistance: Very good
Travel distance: Suitable for drag-chain travel distances greater than 10 m
Screening: Overall tinned-copper braid for EMC-sensitive applications
Compliance options: RoHS compliant, PFAS-free and PWIS-uncritical, subject to HULK product verification

Published configuration range: Multicore versions from 0.50–50 mm² and single-core versions up to 240 mm².

Configuration Largest Single Wire Ø (mm) Approx. Outer Ø (mm) Copper Weight (kg/km) Approx. Cable Weight (kg/km)
2 × 0.50 mm² 0.16 6.8 38.4 55
3 × 0.50 mm² 0.16 7.0 To be confirmed: 44.0 webpage / 34.0 PDF 62
4 × 0.50 mm² 0.16 7.4 51.1 71
5 × 0.50 mm² 0.16 7.9 61.5 83
7 × 0.50 mm² 0.16 9.0 74.1 109
12 × 0.50 mm² 0.16 10.6 108.2 152
18 × 0.50 mm² 0.16 12.2 141.0 214
25 × 0.50 mm² 0.16 14.8 217.0 307
36 × 0.50 mm² 0.16 16.4 275.3 379
52 × 0.50 mm² 0.16 19.2 379.7 524
65 × 0.50 mm² 0.16 21.7 451.5 647
2 × 0.75 mm² 0.16 7.3 46.3 64
3 × 0.75 mm² 0.16 7.6 54.1 74
4 × 0.75 mm² 0.16 8.0 64.0 86
5 × 0.75 mm² 0.16 8.8 74.3 106
7 × 0.75 mm² 0.16 9.8 92.3 129
12 × 0.75 mm² 0.16 11.9 142.4 204
18 × 0.75 mm² 0.16 14.2 215.3 294
25 × 0.75 mm² 0.16 16.6 289.7 386
36 × 0.75 mm² 0.16 18.7 382.6 520
52 × 0.75 mm² 0.16 21.9 514.3 727
65 × 0.75 mm² 0.16 24.5 639.8 868
2 × 1.00 mm² 0.16 7.7 56.5 72
3 × 1.00 mm² 0.16 8.0 66.4 86
4 × 1.00 mm² 0.16 8.5 77.3 98
5 × 1.00 mm² 0.16 9.3 89.0 121
7 × 1.00 mm² 0.16 10.7 117.9 174
12 × 1.00 mm² 0.16 12.8 174.9 248
18 × 1.00 mm² 0.16 15.2 270.2 369
25 × 1.00 mm² 0.16 18.4 367.5 497
36 × 1.00 mm² 0.16 20.3 478.7 657
52 × 1.00 mm² 0.16 23.8 668.9 911
65 × 1.00 mm² 0.16 26.8 805.7 1130
1 × 1.50 mm² 0.16 4.6 24.8 35
2 × 1.50 mm² 0.16 8.3 66.8 87
3 × 1.50 mm² 0.16 8.6 81.5 106
4 × 1.50 mm² 0.16 9.4 101.2 131
5 × 1.50 mm² 0.16 10.1 122.2 149
7 × 1.50 mm² 0.16 11.9 156.8 210
12 × 1.50 mm² 0.16 14.7 269.7 351
18 × 1.50 mm² 0.16 16.9 369.2 483
25 × 1.50 mm² 0.16 20.4 493.4 653
36 × 1.50 mm² 0.16 23.0 660.3 889
52 × 1.50 mm² 0.16 26.9 931.0 1189
65 × 1.50 mm² 0.16 29.9 1132.8 1513
1 × 2.50 mm² 0.16 5.3 38.0 49
2 × 2.50 mm² 0.16 9.9 77.2 122
3 × 2.50 mm² 0.16 10.6 119.7 165
4 × 2.50 mm² 0.16 11.5 150.1 204
5 × 2.50 mm² 0.16 12.6 179.6 249
7 × 2.50 mm² 0.16 15.0 265.2 365
12 × 2.50 mm² 0.16 18.5 417.1 542
18 × 2.50 mm² 0.16 21.6 571.4 767
25 × 2.50 mm² 0.16 26.0 780.8 1036
36 × 2.50 mm² 0.16 28.7 1058.0 1390
52 × 2.50 mm² 0.16 33.0 1479.3 1861
1 × 4.00 mm² 0.16 5.9 54.3 67
2 × 4.00 mm² 0.16 11.6 132.8 181
3 × 4.00 mm² 0.16 12.1 172.9 224
4 × 4.00 mm² 0.16 13.7 216.5 299
5 × 4.00 mm² 0.16 15.0 289.2 357
7 × 4.00 mm² 0.16 18.0 396.3 532
1 × 6.00 mm² 0.21 6.6 75.3 91
2 × 6.00 mm² 0.21 13.7 182.6 251
3 × 6.00 mm² 0.21 14.6 258.8 339
4 × 6.00 mm² 0.21 15.9 328.3 419
5 × 6.00 mm² 0.21 18.0 398.4 523
7 × 6.00 mm² 0.21 20.6 537.3 712
1 × 10.0 mm² 0.21 7.7 117.5 135
3 × 10.0 mm² 0.21 17.4 392.9 517
4 × 10.0 mm² 0.21 18.9 507.7 646
5 × 10.0 mm² 0.21 20.5 615.5 731
1 × 16.0 mm² 0.21 9.1 179.9 208
3 × 16.0 mm² 0.21 20.7 598.4 724
4 × 16.0 mm² 0.21 22.5 758.2 915
5 × 16.0 mm² 0.21 24.7 947.1 1101
1 × 25.0 mm² 0.21 10.7 287.7 300
3 × 25.0 mm² 0.21 23.9 898.2 1039
4 × 25.0 mm² 0.21 25.8 1148.0 1296
5 × 25.0 mm² 0.21 29.1 1400.1 1610
1 × 35.0 mm² 0.21 12.5 390.6 414
4 × 35.0 mm² 0.21 30.1 1546.4 1780
5 × 35.0 mm² 0.21 33.1 1915.1 2119
1 × 50.0 mm² 0.31 15.0 577.2 603
4 × 50.0 mm² 0.31 35.5 2165.3 2613
1 × 70.0 mm² 0.31 17.6 783.1 834
1 × 95.0 mm² 0.31 21.5 1051.2 1139
1 × 120.0 mm² 0.31 22.7 1293.1 1374
1 × 150.0 mm² 0.31 To be confirmed: 25.6 webpage / 26.2 PDF 1611.0 1733
1 × 185.0 mm² 0.41 To be confirmed: 27.9 webpage / 25.6 PDF 1952.4 2086
1 × 240.0 mm² 0.41 31.3 2507.0 2645

Other conductor sizes, core counts, sheath colors and customized dimensions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top