Screened Twisted-Pair Halogen-Free Robot Data Cable 350 V

This screened twisted-pair data cable is designed for reliable signal transmission in robots, long-travel drag chains and highly dynamic automation systems. Its pair-twisted construction supports improved transmission performance and crosstalk attenuation, while the overall tinned-copper screen protects signals against electromagnetic interference.

Key Highlights

Pair-twisted construction · Improved crosstalk attenuation · Overall tinned-copper screen · Good EMC protection · Suitable for robots · Continuous bending and torsional capability · More than 10 million bending cycles · Maximum operating voltage 350 V · Halogen-free insulation · Flame-retardant · Oil- and abrasion-resistant PUR sheath · Compact outer diameter · Long-travel drag-chain capability · Wide temperature range · PFAS-free material option

Suitable for control and monitoring circuits in highly dynamic installations where both mechanical endurance and electromagnetic compatibility are required.

Typical applications include:

  • Industrial robots and robot arms
  • Servo and automated drive systems
  • Long-travel cable chains
  • Machine tools
  • Automated assembly equipment
  • Control circuits near motors and frequency converters
  • Production machinery exposed to oil and chemicals

Conductor: Extra-fine stranded bare copper, based on Class 6 requirements of IEC 60228

Core insulation: Special halogen-free polymer compound

Core identification: Colored cores based on DIN 47100

Pair formation: Individual cores twisted into pairs

Overall stranding: Pairs arranged in mechanically optimized layers with nonwoven tape over each layer

Overall screen: Helically applied or served tinned-copper wires

Wrapping: Nonwoven tape over the screen

Outer sheath: Robust polyurethane compound

Sheath surface: Matte finish

Standard sheath color: Black, similar to RAL 9005

Maximum operating voltage: 350 V

Reference UL/cUL voltage: 300 V

Test voltage:

  • Core to core: 2000 V
  • Core to screen: 2000 V

Reference torsional endurance:

  • Up to ±180° per meter: More than 10 million cycles
  • Up to ±360° per meter: More than 5 million cycles

Minimum bending radius:

  • Fixed installation: 3 × cable diameter
  • Flexible travel up to 5 m: 7.5 × cable diameter
  • Flexible travel over 5 m: 10 × cable diameter

Reference bending endurance: More than 10 million cycles

Temperature range:

  • Fixed installation: −50°C to +90°C
  • Flexible application: −40°C to +90°C
  • Reference UL/cUL temperature: Up to +90°C

Halogen-free performance: According to IEC 60754-1

Flame performance: Flame-retardant and self-extinguishing according to IEC 60332-1-2; reference FT1 and FT2 performance

Oil resistance: Very good

Chemical resistance: Good resistance to acids, alkaline solutions, solvents and hydraulic fluids

Transmission performance: Pair-twisted construction supports reduced crosstalk and stable signal transmission

EMC performance: Overall tinned-copper screen provides protection against electromagnetic interference

Sunlight resistance: According to HD 605

Ozone resistance: According to EN 50396

Saltwater resistance: Reference performance according to UL 1309

Compliance reference: RoHS and PFAS-free material options

Representative dimensions:

Number of Pairs × Cross-Section Largest Single Wire Ø Approx. Outer Ø Copper Weight Approx. Cable Weight
6 × 2 × 0.14 mm² 0.11 mm 6.3 mm 30.0 kg/km 52 kg/km
2 × 2 × 0.25 mm² 0.11 mm 5.2 mm 21.0 kg/km 35 kg/km
4 × 2 × 0.25 mm² 0.11 mm 6.5 mm 33.6 kg/km 52 kg/km
2 × 2 × 0.34 mm² 0.11 mm 5.5 mm 24.8 kg/km 39 kg/km
3 × 2 × 0.34 mm² 0.11 mm 6.0 mm 32.8 kg/km 50 kg/km
4 × 2 × 0.34 mm² 0.11 mm 7.0 mm 42.2 kg/km 61 kg/km
3 × 2 × 0.50 mm² 0.16 mm 7.2 mm 46.1 kg/km 78 kg/km
4 × 2 × 0.50 mm² 0.16 mm 8.2 mm 58.2 kg/km 90 kg/km
4 × 2 × 0.75 mm² 0.16 mm 9.0 mm 79.5 kg/km 107 kg/km

Outer diameter tolerance: Approximately ±10%

Other pair counts, conductor sizes, electrical characteristics and customized dimensions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top