Screened PVC PROFINET Type A Fast-Connect Cable 2 × 2 × 22 AWG

This screened PROFINET Type A cable is designed for fixed Industrial Ethernet installations. Its star-quad construction, combined foil-and-braid screen and PVC sheath provide reliable CAT 5 transmission performance in automation systems. The fast-connect construction supports efficient cable preparation and termination.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Recommended for fixed network connections in industrial automation and process-control equipment.

Typical applications include:

  • PROFINET networks
  • Industrial Ethernet installations
  • PLC and distributed I/O connections
  • Machine tools
  • Automated production lines
  • Control cabinets
  • Factory communication systems
  • EtherCAT and EtherNet/IP networks
  • Fixed connections to sensors, actuators and control equipment

This Type A construction is intended primarily for fixed installation. It should not be specified for continuous drag-chain movement.

Cable assemblies fitted with M12 or RJ45 connectors can be produced on request.

Cable configuration: 2 × 2 × 22 AWG

Conductor: Solid bare copper conductor

Core insulation: Special thermoplastic polymer compound

Core identification: Blue, yellow, white and orange

Core arrangement: Star-quad construction

Core wrapping: PET polyester foil

Inner sheath: PVC compound

Overall screen:

  • Aluminium-laminated foil
  • Tinned-copper wire braid

Outer sheath: PVC compound

Standard sheath color: Green, similar to RAL 6018

Alternative sheath colors and customized constructions are available on request.

Cable category: PROFINET Type A

Transmission category: CAT 5

Peak operating voltage: Maximum 350 V

Reference UL voltage: 300 V

Test voltage:

  • Core to core: 2000 V
  • Core to screen: 2000 V

Characteristic impedance: 100 Ω ± 5 Ω

Reference transmission requirements:

  • EN 50288-2-2
  • VDE 0819-2-2
  • CAT 5 according to EN 50173-1

Minimum bending radius:

  • Fixed installation: 5 × cable diameter

Reference temperature range:

  • Fixed installation: −30°C to +70°C
  • Occasional movement: −5°C to +70°C
  • UL reference temperature: Up to +80°C

Reference UL construction: AWM Style 2464

Oil resistance: Dependent on the selected PVC compound and applicable test requirements

Network compatibility: Suitable for PROFINET, EtherCAT and EtherNet/IP applications when the required system parameters are met

Compliance options: RoHS-compliant and PFAS-free material options

Cable Configuration Maximum Core Ø Approx. Outer Ø Copper Weight Approx. Cable Weight Maximum Conductor Resistance at 20°C
2 × 2 × 22 AWG 1.55 mm 6.5 ± 0.2 mm 32.2 kg/km 66 kg/km 54.1 Ω/km

Final dimensions and electrical values must be confirmed against the approved production drawing.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top