Screened PROFINET Type R Robot Cable

This screened PROFINET Type R cable is designed for robotic systems requiring reliable industrial Ethernet transmission during repeated bending and torsional movement. Extra-fine tinned-copper conductors, combined foil-and-braid shielding and a durable PUR sheath provide flexibility, EMC protection and resistance to industrial oils.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Recommended for robot communication and moving industrial Ethernet connections.

Typical applications include:

  • Industrial robots and robot arms
  • Automated welding and assembly systems
  • Machine tools
  • Material-handling equipment
  • Packaging machinery
  • Industrial Ethernet networks
  • EtherCAT and EtherNet/IP-compatible installations
  • Applications requiring torsional movement up to ±180° per meter

The cable should be matched with suitable industrial connectors and tested as a complete communication channel.

Component Construction
Conductor Extra-fine stranded tinned copper
Core insulation Polyethylene compound
Core identification Blue, yellow, white and orange
Pair formation Two twisted pairs
Overall stranding Pairs stranded together in layers
Inner wrapping Netting tape and aluminum-laminated foil
Overall screen Tinned-copper wire braid
Screen wrapping Nonwoven tape
Outer sheath Oil- and abrasion-resistant polyurethane compound
Standard sheath color Green, similar to RAL 6018
Standard configuration 2 × 2 × 22 AWG
Property Reference Value
Maximum operating voltage 350 V
Test voltage, core to core 1500 V
Test voltage, core to screen 1200 V
Maximum conductor DC resistance 58 Ω/km
Characteristic impedance 100 Ω ±10 Ω
Transmission category CAT 5
Transmission standard references EN 50173-1 and EN 50288-2-2
Minimum bending radius, fixed 5 × cable diameter
Minimum bending radius, flexible 10 × cable diameter
Reference torsional capability Up to ±180° per meter
Temperature range, fixed −40°C to +70°C
Temperature range, flexible −30°C to +70°C
Halogen-free performance According to IEC 60754-1
Oil resistance According to applicable PUR requirements of EN 50363-10-2
Configuration Approx. Outer Ø Copper Weight Approx. Cable Weight Maximum DC Resistance
2 × 2 × 22 AWG 7.0 mm 36.3 kg/km 62 kg/km 58 Ω/km

Outer diameter tolerance: Approximately ±10%

Customized sheath colors, connector assemblies and application-specific constructions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top