Screened PFA High-Temperature Sensor Cable up to 250°C

This miniature screened sensor cable uses silver-plated copper conductors with PFA insulation and a PFA outer sheath for operation across an exceptionally wide temperature range. Its compact diameter, low dielectric constant and strong resistance to chemicals, fuels, oils, battery acid and weathering make it suitable for demanding measurement and testing systems.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Designed for low-voltage sensor and measurement circuits exposed to extreme temperatures or aggressive media.

Typical applications include:

  • High-temperature sensors
  • Miniature sensor systems
  • Strain gauges
  • Measurement and testing technology
  • Laboratory equipment
  • Battery-testing systems
  • Chemical-processing instrumentation
  • Engine and powertrain test equipment
  • Outdoor measuring installations
  • Modular test and measurement assemblies
Component Construction
Conductor Silver-plated stranded copper
Core insulation PFA
Core identification Color-coded with reference to DIN 47100
Wrapping Foil
Overall screen Tinned-copper wire braid
Minimum screen coverage 85% optical coverage
Outer sheath PFA
Standard sheath color Black, similar to RAL 9005
Optional construction Unscreened and ready-assembled versions available on request
Property Reference Value
Maximum operating voltage 48 V
Test voltage, core to core 600 V
Test voltage, core to screen 600 V
Minimum bending radius, one-time fixed bend 2 × cable diameter
Minimum bending radius, flexible installation 10 × cable diameter
Temperature range, fixed installation −90°C to +250°C
Temperature range, flexible installation −55°C to +250°C
Relative dielectric constant Approximately 2.1
Flame performance Flame-retardant and self-extinguishing according to IEC 60332-1-2
Oil resistance Very good
Hydraulic-fluid resistance Very good
Fuel resistance Very good
Battery-acid resistance Very good
UV resistance Very good
Ozone resistance Very good
Saltwater resistance Very good
Chemical resistance Very good, subject to chemical concentration and exposure conditions
EMC performance Tinned-copper braid with at least 85% optical coverage
Compliance option RoHS-compliant materials, subject to confirmation
Configuration Approx. Outer Ø Copper Weight Approx. Cable Weight
2 × AWG 34/7 1.8 mm 5.7 kg/km 8 kg/km
3 × AWG 30/7 2.1 mm 8.7 kg/km 11 kg/km
4 × AWG 32/7 2.1 mm 8.1 kg/km 11 kg/km
6 × AWG 28/7 2.7 mm 16.0 kg/km 20 kg/km

Outer diameter tolerance: Approximately ±10%

Additional conductor sizes, core counts, colors and ready-assembled versions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top