Screened PFA High-Temperature Sensor Cable up to 250°C
This miniature screened sensor cable uses silver-plated copper conductors with PFA insulation and a PFA outer sheath for operation across an exceptionally wide temperature range. Its compact diameter, low dielectric constant and strong resistance to chemicals, fuels, oils, battery acid and weathering make it suitable for demanding measurement and testing systems.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
Designed for low-voltage sensor and measurement circuits exposed to extreme temperatures or aggressive media.
Typical applications include:
- High-temperature sensors
- Miniature sensor systems
- Strain gauges
- Measurement and testing technology
- Laboratory equipment
- Battery-testing systems
- Chemical-processing instrumentation
- Engine and powertrain test equipment
- Outdoor measuring installations
- Modular test and measurement assemblies
| Component | Construction |
| Conductor | Silver-plated stranded copper |
| Core insulation | PFA |
| Core identification | Color-coded with reference to DIN 47100 |
| Wrapping | Foil |
| Overall screen | Tinned-copper wire braid |
| Minimum screen coverage | 85% optical coverage |
| Outer sheath | PFA |
| Standard sheath color | Black, similar to RAL 9005 |
| Optional construction | Unscreened and ready-assembled versions available on request |
| Property | Reference Value |
| Maximum operating voltage | 48 V |
| Test voltage, core to core | 600 V |
| Test voltage, core to screen | 600 V |
| Minimum bending radius, one-time fixed bend | 2 × cable diameter |
| Minimum bending radius, flexible installation | 10 × cable diameter |
| Temperature range, fixed installation | −90°C to +250°C |
| Temperature range, flexible installation | −55°C to +250°C |
| Relative dielectric constant | Approximately 2.1 |
| Flame performance | Flame-retardant and self-extinguishing according to IEC 60332-1-2 |
| Oil resistance | Very good |
| Hydraulic-fluid resistance | Very good |
| Fuel resistance | Very good |
| Battery-acid resistance | Very good |
| UV resistance | Very good |
| Ozone resistance | Very good |
| Saltwater resistance | Very good |
| Chemical resistance | Very good, subject to chemical concentration and exposure conditions |
| EMC performance | Tinned-copper braid with at least 85% optical coverage |
| Compliance option | RoHS-compliant materials, subject to confirmation |
| Configuration | Approx. Outer Ø | Copper Weight | Approx. Cable Weight |
| 2 × AWG 34/7 | 1.8 mm | 5.7 kg/km | 8 kg/km |
| 3 × AWG 30/7 | 2.1 mm | 8.7 kg/km | 11 kg/km |
| 4 × AWG 32/7 | 2.1 mm | 8.1 kg/km | 11 kg/km |
| 6 × AWG 28/7 | 2.7 mm | 16.0 kg/km | 20 kg/km |
Outer diameter tolerance: Approximately ±10%
Additional conductor sizes, core counts, colors and ready-assembled versions are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity