Screened Low-Capacitance PUR Motor Cable 0.6/1 kV

This screened 0.6/1 kV motor cable is designed for frequency-controlled drives, servo motors and continuously moving industrial machinery. Its low-capacitance insulation system, Class 6 flexible conductors, overall tinned-copper braid and robust PUR sheath support reliable power transmission with effective electromagnetic interference protection.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Recommended for connecting frequency converters, servo drives and industrial motors in fixed and flexible installations.

Typical applications include:

  • Variable-frequency drive systems
  • Servo motors and drive controllers
  • Cable tracks and energy chains
  • Machine tools
  • Automated production equipment
  • Packaging and processing machinery
  • Material-handling systems
  • Industrial installations exposed to oil and chemicals

The cable is designed for repeated bending in guided installations. Applications involving continuous torsion require a separately qualified cable construction.

Component Description
Conductor Fine-stranded bare copper, Class 6 based on IEC 60228
Core insulation Special low-capacitance polymer compound
Core identification Black power cores with consecutive white numbers
Protective conductor Green/yellow earth core
Core assembly Cores stranded in movement-optimized layers
Inner wrapping Nonwoven tape
Overall screen Tinned-copper wire braid
Outer sheath Oil- and abrasion-resistant polyurethane
Standard sheath color Orange, similar to RAL 2003
Property Reference Value
Nominal voltage U₀/U 0.6/1 kV
Reference North American voltage 1000 V, certification-dependent
Test voltage, core to core 4000 V
Test voltage, core to screen 4000 V
Fixed bending radius 5 × cable diameter
Flexible bending radius 10 × cable diameter
Fixed temperature range −50°C to +90°C
Flexible temperature range −40°C to +90°C
Reference North American temperature Up to +80°C, certification-dependent
Halogen-free performance Based on IEC 60754-1
Flame performance Based on IEC 60332-1-2
Oil resistance PUR performance based on EN 50363-10-2
Chemical resistance Good resistance to acids, alkaline solutions, solvents and hydraulic fluids
EMC performance Overall copper braid helps reduce radiated and conducted interference
Compliance options RoHS- and PFAS-free material options, subject to confirmation

Representative dimensions:

Number of Cores × Cross-Section AWG Reference Largest Single Wire Ø Approx. Outer Ø Copper Weight Approx. Cable Weight
4 × 1.50 mm² 16/4c 0.16 mm 9.0 mm 83.5 kg/km 126 kg/km
4 × 2.50 mm² 14/4c 0.16 mm 10.8 mm 142.5 kg/km 195 kg/km
4 × 4.00 mm² 12/4c 0.16 mm 12.4 mm 206.5 kg/km 270 kg/km
4 × 6.00 mm² 10/4c 0.21 mm 15.4 mm 298.1 kg/km 398 kg/km
4 × 10.00 mm² 8/4c 0.21 mm 17.6 mm 494.7 kg/km 604 kg/km
4 × 16.00 mm² 6/4c 0.21 mm 22.7 mm 749.7 kg/km 953 kg/km

Outer diameter tolerance: Approximately ±10%.

Constructions up to 4 × 50 mm² and other application-specific conductor sizes are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top