Screened Heavy-Duty Flexible TPE Tray Cable 600 V
This screened heavy-duty tray cable features Class K stranded copper conductors, PVC/Nylon core insulation, a black PVC inner sheath and an overall tinned-copper braid. Its durable TPE outer sheath provides strong resistance to oil, sunlight and low-temperature industrial conditions.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
Designed for control and instrumentation circuits requiring both heavy-duty mechanical performance and electromagnetic interference protection.
Typical applications include:
- Machine tools and CNC systems
- Automotive production machinery
- Automated assembly equipment
- Industrial control and instrumentation systems
- Motors, drives and electrically noisy equipment
- Grinding and processing machinery
- Packaging and bottling lines
- Panel-to-machine connections
- Cable trays and exposed industrial runs
- Hazardous industrial locations where approved
Conductor: Flexible bare copper strands based on Class K requirements
Core insulation: Specially formulated PVC/Nylon compound
Core identification: Black cores with consecutive white alphanumeric numbering
Protective conductor: Green/yellow earth core where required
Stranding: Cores stranded in layers
Inner sheath: Black PVC compound
Overall screen: Tinned-copper wire braid
Outer sheath: Heavy-duty thermoplastic elastomer compound
Standard sheath color: Orange, similar to RAL 2003
Optional sheath colors: Grey or black
Optional core colors: Blue, red or customized colors
Reference voltage:
- UL AWM, Type TC and cUL applications: 600 V
- WTTC reference rating: 1000 V
Test voltage: 2000 V
Minimum bending radius: 7.5 × cable diameter
Temperature references:
- UL AWM maximum temperature: +105°C
- UL/cUL/CSA AWM maximum temperature: +90°C
- Type TC reference: +90°C dry and +75°C wet
- Fixed installation under UL AWM reference: Down to −40°C
Cold-bend test reference: −40°C
Reference flame performance: UL FT4 and cUL FT1, FT2 and FT4
Oil resistance: Oil Resistance I and II reference
Sunlight resistance: Yes
EMC performance: Overall tinned-copper braid helps protect circuits against electromagnetic interference
Installation references: Exposed Run and Direct Burial
Hazardous-location reference: Class I, Division 2 under the applicable NEC requirements
Design and compliance references: UL Type TC-ER, UL 1277, WTTC, AWM Style 21270, shielded cUL CIC-TC, CSA AWM and NFPA 79
Material compliance references: RoHS-compliant and PFAS-free material options
Representative reference dimensions:
| Conductor Configuration | Approx. Outer Ø | Approx. Cable Weight |
| 4 × 18 AWG | 9.7 mm | 131 kg/km |
| 4 × 16 AWG | 10.4 mm | 159 kg/km |
| 4 × 14 AWG | 12.1 mm | 221 kg/km |
| 4 × 12 AWG | 13.2 mm | 323 kg/km |
| 4 × 8 AWG | 22.7 mm | 868 kg/km |
| 4 × 1 AWG | 39.0 mm | 4189 kg/km |
Outer-diameter tolerance: Approximately ±10%
Finished diameter and weight depend on conductor configuration, screen coverage, inner-sheath thickness and required approvals.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity