Screened Halogen-Free PUR Offshore Exploration Cable 0.6/1 kV
This robust, highly flexible 0.6/1 kV cable is designed for control and power connections in demanding onshore and offshore environments. Its overall tinned-copper braid, high-strength supporting yarn and durable PUR outer sheath provide reliable performance in applications exposed to oil, drilling mud, salt water, sunlight, ozone and low temperatures.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
Designed for electrical control and power connections in harsh exploration, drilling and industrial environments.
Typical applications include:
- Onshore and offshore drilling equipment
- Topside drilling loops
- Oil and gas exploration systems
- Drilling rigs and auxiliary equipment
- Compressors and industrial pumps
- Offshore processing equipment
- Wet areas of machine tools
- Production and processing lines
- Equipment exposed to drilling mud or salt water
- Protected installations involving occasional movement
Application-specific hybrid constructions combining power, control or signal elements are available on request.
Conductor: Fine-stranded bare copper, Class 5 according to IEC 60228
Core insulation: Special halogen-free polymer compound
Core identification:
- Up to four cores: Colored cores according to HD 308
- Five cores and above: Black cores with consecutive white numbers
- Protective conductor: Green/yellow core where required
Overall screen: Tinned-copper wire braid
Supporting layer: High-strength technical yarn for improved mechanical load distribution
Outer sheath: Oil- and abrasion-resistant thermoplastic polyurethane based on TMPU requirements of EN 50363-10-2
Standard sheath color: Black, similar to RAL 9005
Optional construction: Hybrid power, control and signal combinations available on request
Nominal voltage: U₀/U 0.6/1 kV
Reference cULus voltage: 1000 V
Test voltage:
- Core to core: 4000 V
- Core to screen: 4000 V
Current-carrying capacity: Based on the applicable requirements of VDE 0298-4
Minimum bending radius:
- Fixed installation: 6 × cable diameter
- Flexible or occasionally moving application: 15 × cable diameter
Temperature range:
- Fixed installation: −50°C to +90°C
- Protected flexible installation with occasional movement: −45°C to +90°C
- Reference cULus temperature: Up to +80°C
Cold resistance: Reference performance at −50°C according to DIN EN 60811-506
Halogen-free performance: According to IEC 60754-1
Flame performance:
- Flame-retardant and self-extinguishing according to IEC 60332-1-2
- Reference cUL FT1 and FT2 performance
Oil resistance: Very good, based on TMPU requirements of EN 50363-10-2
Drilling-mud resistance: Very good, with reference to IEC 60092-350, IEC 61892-4 and NEK TS 606
Saltwater resistance: Reference performance according to UL 1309
Sunlight resistance: According to HD 605
Ozone resistance: According to DIN EN 50396
Maximum tensile load reference: 20 N/mm²
EMC performance: Overall tinned-copper braid helps protect control and power circuits against electromagnetic interference
Material compliance references: RoHS-compliant and PFAS-free material options
Representative reference dimensions:
| Number of Cores × Cross-Section | Largest Single Wire Ø | Approx. Outer Ø | Copper Weight | Approx. Cable Weight |
| 7 × 1.50 mm² | 0.26 mm | 11.3 mm | 149.0 kg/km | 208 kg/km |
| 12 × 1.50 mm² | 0.26 mm | 13.2 mm | 232.5 kg/km | 288 kg/km |
| 5 × 2.50 mm² | 0.26 mm | 11.0 mm | 179.0 kg/km | 221 kg/km |
| 4 × 4.00 mm² | 0.31 mm | 12.2 mm | 207.6 kg/km | 271 kg/km |
| 4 × 10.00 mm² | 0.41 mm | 16.6 mm | 471.9 kg/km | 561 kg/km |
| 4 × 25.00 mm² | 0.41 mm | 25.0 mm | 1056.6 kg/km | 1275 kg/km |
| 1 × 70.00 mm² | 0.41 mm | 19.8 mm | 784.0 kg/km | 862 kg/km |
| 1 × 300.00 mm² | 0.51 mm | 37.5 mm | 3077.6 kg/km | 3445 kg/km |
Outer-diameter tolerance: Approximately ±10%
Available reference range:
- Multi-core control and power constructions: 1.50–50.00 mm²
- Single-core power constructions: 35.00–300.00 mm²
Additional conductor sizes, core counts, hybrid combinations and customized electrical characteristics are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity