Screened Halogen-Free PUR Festoon Cable with Support Core 0.6/1 kV

This screened halogen-free festoon cable combines Class 5 copper conductors, TPE insulation, an integrated support unit and an overall tinned-copper braid. It is designed for high-speed cable roller assemblies and suspended moving systems requiring reliable power transmission, mechanical durability and electromagnetic compatibility.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Recommended for power, control and monitoring circuits in festoon and cable roller systems where protection against electromagnetic interference is required.

Typical applications include:

  • Festoon cable trolley systems
  • Electrically controlled crane equipment
  • Gantry and bridge cranes
  • Port and container-handling systems
  • Cable roller assemblies
  • Material-handling machinery
  • Equipment operating near motors and frequency converters
  • Suspended moving cables carrying interference-sensitive circuits
  • Selected simple reeling applications

Multi-core versions incorporate an internal support unit. Single-core versions are manufactured without the support unit.

Conductor: Flexible bare-copper strands, Class 5 according to IEC 60228 and VDE 0295

Core insulation: Thermoplastic elastomer compound

Core identification:

  • Single-core versions: Black
  • Two- to five-core versions: Colored cores according to HD 308 and VDE 0293-308
  • Six or more cores: Black cores with consecutive white numbers according to EN 50334 and VDE 0293-334

Protective conductor: Green/yellow core included from three-core versions where required

Stranding: Specially adjusted layered construction with an integrated support unit

Single-core construction: Supplied without an internal support unit

Inner wrapping: Nonwoven tape

Overall screen: Tinned-copper wire braid

Screen wrapping: Nonwoven tape

Outer sheath: Polyurethane compound, TMPU according to EN 50363-10-2 and VDE 0207-363-10-2

Standard sheath color: Black, similar to RAL 9005

Nominal voltage: U₀/U 0.6/1 kV

Test voltage:

  • Core to core: 4000 V
  • Core to screen: 4000 V

Minimum bending radius: 7.5 × cable diameter

Maximum continuous tensile load: 15 N/mm² according to VDE 0298-3, Section 7.1

Temperature range:

  • Fixed installation: −50°C to +90°C
  • Flexible application: −40°C to +90°C

Reference maximum travel speed in cable roller assemblies: 240 m/min

Simple reeling operation: Permitted subject to application and system validation

Halogen-free performance: According to IEC 60754-1 and VDE 0482-754-1

Oil resistance: Very good according to the referenced TMPU requirements

Chemical resistance: Good resistance to acids, alkaline solutions, solvents and hydraulic fluids

Continuous flexibility: Very good

Weather resistance: Very good

EMC performance: Overall tinned-copper braid provides electromagnetic shielding

Reference compliance: CE, RoHS and PFAS-free material designation

Representative dimensions:

Number of Cores × Cross-Section Largest Single Wire Ø Approx. Outer Ø Copper Weight Approx. Cable Weight
2 × 1.50 mm² 0.26 mm 7.5 mm 49.1 kg/km 81 kg/km
7 G 1.50 mm² 0.26 mm 11.2 mm 152.5 kg/km 202 kg/km
12 G 1.50 mm² 0.26 mm 13.3 mm 234.0 kg/km 286 kg/km
18 G 1.50 mm² 0.26 mm 16.3 mm 358.2 kg/km 443 kg/km
4 G 2.50 mm² 0.26 mm 10.2 mm 141.8 kg/km 177 kg/km
18 G 2.50 mm² 0.26 mm 19.0 mm 546.4 kg/km 643 kg/km
4 G 6.00 mm² 0.31 mm 14.2 mm 292.5 kg/km 366 kg/km
4 G 16.00 mm² 0.41 mm 22.0 mm 749.7 kg/km 903 kg/km
4 G 25.00 mm² 0.41 mm 25.8 mm 1121.8 kg/km 1302 kg/km
1 × 50.00 mm² 0.41 mm 14.6 mm 577.2 kg/km 607 kg/km
4 G 50.00 mm² 0.41 mm 33.4 mm 2129.6 kg/km 2460 kg/km
1 × 120.00 mm² 0.51 mm 21.9 mm 1293.1 kg/km 1311 kg/km

Outer diameter tolerance: Approximately ±10%

Copper weight includes the overall tinned-copper screen. Finished dimensions and screen coverage must be confirmed against the approved production drawing.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top