This combined servo motor cable integrates 0.6/1 kV motor-supply conductors with one or two screened control or brake pairs. A low-capacitance insulation system, individually screened control elements, an overall copper braid and a durable PUR sheath support compact installation in dynamic servo-drive systems.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Recommended for servo motors requiring motor power plus brake, temperature-monitoring or auxiliary control circuits in the same cable.

Typical applications include:

  • Servo motors and drive controllers
  • Motor brake circuits
  • Temperature-sensor and auxiliary-control connections
  • CNC machinery
  • Automated assembly systems
  • Packaging equipment
  • Industrial robots without continuous torsion
  • Cable tracks and energy chains

This construction combines motor power with auxiliary control pairs. It is not a substitute for a full encoder or digital-feedback hybrid cable unless the required feedback interface has been specifically engineered and tested.

Component Description
Conductor Fine-stranded bare copper, Class 6 based on IEC 60228
Core insulation Special halogen-free, low-capacitance polymer compound
Power-core identification Black numbered cores with green/yellow protective-earth conductor
Control-core identification Numbered, black/white or application-specific identification
Control formation Control conductors twisted into pairs
Control-pair screen Aluminum-laminated foil and tinned-copper wire braid
Pair wrapping Protective polymer foil
Overall assembly Screened control pairs and supply cores stranded with fillers
Inner wrapping Nonwoven tape
Overall screen Tinned-copper wire braid
Screen wrapping Nonwoven tape
Outer sheath Matte oil- and abrasion-resistant polyurethane
Standard sheath color Orange, similar to RAL 2003
Property Reference Value
Nominal voltage, supply conductors U₀/U 0.6/1 kV
Peak operating voltage, control conductors Maximum 350 V
Reference North American voltage 1000 V, certification-dependent
Test voltage, supply core to core 4000 V
Test voltage, supply core to screen 4000 V
Test voltage, control core to core 2000 V
Test voltage, control core to screen 2000 V
Fixed bending radius 5 × cable diameter
Flexible bending radius 10 × cable diameter
Fixed temperature range −50°C to +90°C
Flexible temperature range −40°C to +90°C
Reference North American temperature Up to +80°C, certification-dependent
Halogen-free performance Based on IEC 60754-1
Flame performance Based on IEC 60332-1-2
Oil resistance PUR performance based on EN 50363-10-2
Chemical resistance Good resistance to acids, alkaline solutions, solvents and hydraulic fluids
Weather resistance Very good reference performance
Compliance options RoHS-, PFAS-free and PWIS-compatible material options

Representative configurations:

Cable Configuration Approx. Outer Ø Copper Weight Approx. Cable Weight
4 × 1.00 mm² + screened 2 × 0.50 mm² 9.0 ± 0.8 mm 88.2 kg/km 120 kg/km
4 × 1.50 mm² + screened 2 × 0.50 mm² 9.5 ± 0.8 mm 108.0 kg/km 142 kg/km
4 × 1.50 mm² + screened 2 × 1.50 mm² 10.7 ± 0.8 mm 150.5 kg/km 189 kg/km
4 × 1.50 mm² + 2 × screened 2 × 0.75 mm² 11.4 ± 0.8 mm 166.5 kg/km 211 kg/km
4 × 4.00 mm² + screened 2 × 1.00 mm² + screened 2 × 1.50 mm² 15.0 ± 0.8 mm 303.2 kg/km 373 kg/km
4 × 6.00 mm² + screened 2 × 1.50 mm² 16.3 ± 0.8 mm 376.8 kg/km 450 kg/km
4 × 10.00 mm² + screened 2 × 1.00 mm² + screened 2 × 1.50 mm² 19.3 ± 0.8 mm 581.3 kg/km 692 kg/km
4 × 16.00 mm² + 2 × screened 2 × 1.50 mm² 22.9 ± 0.8 mm 860.1 kg/km 1012 kg/km

Additional power sizes, control-pair combinations and drive-specific core-identification systems are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top