LiYY Flexible PVC Data Cable

This flexible, unshielded PVC data cable features a compact outer diameter and small bending radius. It is designed for low-voltage signal, measurement and control connections inside electronic equipment, control panels, switchboards and communication devices.

Key Highlights

Flexible unshielded construction · Compact outer diameter · Small bending radius · DIN 47100 reference colour code · Wide range of core configurations · Flame-retardant and self-extinguishing · RoHS compliant · PFAS-free

Recommended for flexible interconnections in protected, dry industrial and commercial environments.

Typical applications include:

  • Electronic weighing scales
  • Control panels and control cabinets
  • Low-voltage switchboards
  • Communication equipment
  • Electrical and electronic appliances
  • Measurement and control devices
  • Internal equipment wiring
  • Conductor: flexible stranded bare copper with reference to VDE 0812
  • Core insulation: PVC TI2 according to EN 50363-3 and VDE 0207-363-3
  • Core identification: colour-coded with reference to DIN 47100
  • Core assembly: cores stranded in concentric layers
  • Outer sheath: PVC TM2 according to EN 50363-4-1 and VDE 0207-363-4-1
  • Standard sheath colour: grey, similar to RAL 7032
  • Shielding: unshielded
  • Peak operating voltage below 0.25 mm²: maximum 350 V
  • Peak operating voltage from 0.25 mm²: maximum 500 V
  • Test voltage, core-to-core: 1,500 V
  • Minimum bending radius for fixed installation: 5 × cable diameter
  • Minimum bending radius for flexible application: 10 × cable diameter
  • Fixed installation temperature: -30°C to +70°C
  • Flexible application temperature: -5°C to +70°C
  • Radiation resistance: 8 × 10⁷ cJ/kg
  • Capacitance: depends on conductor size and cable construction
  • Flame performance: flame-retardant and self-extinguishing
  • Flame test: IEC 60332-1-2 and VDE 0482-332-1-2
  • Oil resistance: according to the selected material specification
  • Chemical resistance: dependent on the chemical medium and exposure conditions
  • Environmental compliance: RoHS compliant and PFAS-free
Core Configuration Approx. Outer Ø ±10% (mm) Copper Weight (kg/km) Approx. Cable Weight (kg/km)
2 × 0.14 mm² 3.1 2.7 13
3 × 0.14 mm² 3.3 4.0 15
4 × 0.14 mm² 3.5 5.4 17
5 × 0.14 mm² 3.8 6.7 21
6 × 0.14 mm² 4.1 8.1 25
7 × 0.14 mm² 4.1 9.4 25
8 × 0.14 mm² 4.7 10.8 33
10 × 0.14 mm² 5.1 13.4 34
12 × 0.14 mm² 5.3 16.1 39
14 × 0.14 mm² 5.5 18.8 44
16 × 0.14 mm² 6.0 21.5 53
18 × 0.14 mm² 6.3 24.2 59
20 × 0.14 mm² 6.6 26.9 65
21 × 0.14 mm² 6.9 28.2 69
24 × 0.14 mm² 7.3 32.3 73
25 × 0.14 mm² 7.7 33.6 79
27 × 0.14 mm² 7.7 36.3 83
30 × 0.14 mm² 7.9 40.3 90
32 × 0.14 mm² 8.2 43.0 97
36 × 0.14 mm² 8.5 48.4 107
40 × 0.14 mm² 9.1 53.8 119
44 × 0.14 mm² 9.5 59.1 126
48 × 0.14 mm² 10.1 64.5 144
50 × 0.14 mm² 10.3 67.2 149
52 × 0.14 mm² 10.3 69.9 154
56 × 0.14 mm² 10.6 75.3 165
61 × 0.14 mm² 10.9 82.0 175
2 × 0.25 mm² 3.4 4.8 16
3 × 0.25 mm² 3.6 7.2 20
4 × 0.25 mm² 3.9 9.6 24
5 × 0.25 mm² 4.2 12.0 29
6 × 0.25 mm² 4.6 14.4 34
7 × 0.25 mm² 4.6 16.8 35
8 × 0.25 mm² 5.2 19.2 45
9 × 0.25 mm² 5.6 21.6 51
10 × 0.25 mm² 5.9 24.0 51
12 × 0.25 mm² 6.1 28.8 58
14 × 0.25 mm² 6.4 33.6 66
16 × 0.25 mm² 6.7 38.4 74
18 × 0.25 mm² 7.1 43.2 83
20 × 0.25 mm² 7.6 48.0 95
21 × 0.25 mm² 7.9 50.4 100
24 × 0.25 mm² 8.4 57.6 108
25 × 0.25 mm² 8.6 60.0 112
27 × 0.25 mm² 8.6 64.8 119
30 × 0.25 mm² 8.9 72.0 131
32 × 0.25 mm² 9.2 76.8 139
36 × 0.25 mm² 10.0 86.4 163
40 × 0.25 mm² 10.6 96.0 181
44 × 0.25 mm² 11.1 105.6 192
48 × 0.25 mm² 11.3 115.2 206
50 × 0.25 mm² 11.6 120.0 214
52 × 0.25 mm² 11.6 124.8 221
56 × 0.25 mm² 11.9 134.4 237
61 × 0.25 mm² 12.3 146.4 254
2 × 0.34 mm² 4.0 6.5 23
3 × 0.34 mm² 4.2 9.8 27
4 × 0.34 mm² 4.6 13.1 33
5 × 0.34 mm² 5.0 16.3 41
6 × 0.34 mm² 5.5 19.6 49
7 × 0.34 mm² 5.5 22.8 51
8 × 0.34 mm² 6.5 26.1 67
10 × 0.34 mm² 7.1 32.6 72
12 × 0.34 mm² 7.3 39.2 83
14 × 0.34 mm² 7.9 45.7 98
16 × 0.34 mm² 8.3 52.2 111
18 × 0.34 mm² 8.8 58.8 124
20 × 0.34 mm² 9.2 65.3 137
21 × 0.34 mm² 10.0 68.5 153
24 × 0.34 mm² 10.6 78.3 165
25 × 0.34 mm² 10.8 81.6 170
27 × 0.34 mm² 10.8 88.1 181
30 × 0.34 mm² 11.2 97.9 197
32 × 0.34 mm² 11.6 104.4 210
36 × 0.34 mm² 12.1 117.5 234
40 × 0.34 mm² 12.9 130.6 261
44 × 0.34 mm² 13.5 143.6 277
48 × 0.34 mm² 13.7 156.7 298
52 × 0.34 mm² 14.5 169.7 333
56 × 0.34 mm² 14.9 182.8 356
61 × 0.34 mm² 15.4 199.1 382
2 × 0.50 mm² 4.3 9.6 27
3 × 0.50 mm² 4.5 14.4 33
4 × 0.50 mm² 4.9 19.2 40
5 × 0.50 mm² 5.4 24.0 50
6 × 0.50 mm² 6.1 28.8 62
7 × 0.50 mm² 6.1 33.6 65
8 × 0.50 mm² 7.1 38.4 83
10 × 0.50 mm² 7.9 48.0 92
12 × 0.50 mm² 8.1 57.6 106
14 × 0.50 mm² 8.5 67.2 120
16 × 0.50 mm² 9.0 76.8 137
18 × 0.50 mm² 9.5 86.4 152
20 × 0.50 mm² 10.4 96.0 178
21 × 0.50 mm² 10.9 100.8 189
24 × 0.50 mm² 11.5 115.2 203
25 × 0.50 mm² 11.7 120.0 210
27 × 0.50 mm² 11.7 129.6 223
30 × 0.50 mm² 12.1 144.0 244
32 × 0.50 mm² 12.6 153.6 261
36 × 0.50 mm² 13.1 172.8 290
40 × 0.50 mm² 14.5 192.0 337
44 × 0.50 mm² 15.1 211.2 358
48 × 0.50 mm² 15.3 230.4 384
52 × 0.50 mm² 15.7 249.6 412
56 × 0.50 mm² 16.2 268.8 442
61 × 0.50 mm² 16.7 292.8 475
2 × 0.75 mm² 4.9 14.4 37
3 × 0.75 mm² 5.2 21.6 45
4 × 0.75 mm² 5.9 28.8 58
5 × 0.75 mm² 6.4 36.0 71
6 × 0.75 mm² 7.0 43.2 84
7 × 0.75 mm² 7.0 50.4 89
8 × 0.75 mm² 8.3 57.6 116
10 × 0.75 mm² 9.1 72.0 127
12 × 0.75 mm² 9.4 86.4 146
14 × 0.75 mm² 10.3 100.8 175
16 × 0.75 mm² 10.8 115.2 198
18 × 0.75 mm² 11.4 129.6 221
21 × 0.75 mm² 12.5 151.2 260
24 × 0.75 mm² 13.3 172.8 280
27 × 0.75 mm² 13.6 194.4 309
30 × 0.75 mm² 14.5 216.0 351
32 × 0.75 mm² 15.0 230.4 375
36 × 0.75 mm² 15.6 259.2 417
2 × 1.00 mm² 5.1 19.2 43
3 × 1.00 mm² 5.4 28.8 54
4 × 1.00 mm² 6.1 38.4 70
5 × 1.00 mm² 6.7 48.0 87
6 × 1.00 mm² 7.3 57.6 103
7 × 1.00 mm² 7.3 67.2 110
2 × 1.50 mm² 5.6 28.8 54
3 × 1.50 mm² 6.1 43.2 70
4 × 1.50 mm² 6.7 57.6 87
5 × 1.50 mm² 7.7 72.0 115
6 × 1.50 mm² 8.4 86.4 136
7 × 1.50 mm² 8.4 100.8 146

Other core configurations, conductor sizes, sheath colours and customized dimensions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top