LiYCY (B) TP Shielded Twisted Pair PVC Data Cable

This flexible PVC data cable combines twisted-pair construction with an overall tinned copper braid and drain wire. It is designed for measurement, control, communication and voice signals requiring improved electromagnetic compatibility and compact installation dimensions.

Key Highlights

Twisted-pair construction · Overall tinned copper braid · Tinned copper drain wire · Good EMC performance · Flexible and compact design · Small bending radius · DIN 47100 reference colour code · RoHS compliant · PFAS-free

Suitable for EMC-sensitive signal connections in:

  • Measurement and control equipment
  • Low-voltage switchboards
  • Electronic weighing systems
  • Communication devices
  • Office and computing equipment
  • Electrical appliance engineering
  • Industrial instrumentation systems
  • Conductor: flexible stranded bare copper with reference to VDE 0812
  • Core insulation: PVC TI2 according to EN 50363-3 and VDE 0207-363-3
  • Core identification: colour-coded with reference to DIN 47100
  • Pair construction: two cores twisted into pairs
  • Cable assembly: pairs stranded in layers
  • Inner wrapping: PETP foil
  • Overall screen: tinned copper braid
  • Drain wire: 0.34 mm² tinned copper
  • Outer sheath: PVC TM2 according to EN 50363-4-1 and VDE 0207-363-4-1
  • Standard sheath colour: grey, similar to RAL 7032
  • Peak operating voltage below 0.25 mm²: maximum 350 V
  • Peak operating voltage from 0.25 mm²: maximum 500 V
  • Test voltage, core-to-core: 1,500 V
  • Test voltage, core-to-screen: 1,200 V
  • Minimum bending radius for fixed installation: 5 × cable diameter
  • Minimum bending radius for flexible application: 10 × cable diameter
  • Fixed installation temperature: -30°C to +70°C
  • Flexible application temperature: -5°C to +70°C
  • Radiation resistance: 8 × 10⁷ cJ/kg
  • Capacitance: depends on conductor size and pair configuration
  • Flame test: IEC 60332-1-2 and VDE 0482-332-1-2
  • Flame performance: flame-retardant and self-extinguishing
  • Oil and chemical resistance: dependent on the selected material specification
  • Environmental compliance: RoHS compliant and PFAS-free
Pair Configuration Approx. Outer Ø ±10% (mm) Copper Weight (kg/km) Approx. Cable Weight (kg/km)
2 × 2 × 0.14 mm² 5.2 19.1 34
3 × 2 × 0.14 mm² 5.7 23.4 41
4 × 2 × 0.14 mm² 6.5 27.8 53
5 × 2 × 0.14 mm² 7.0 31.9 60
6 × 2 × 0.14 mm² 7.2 36.2 68
8 × 2 × 0.14 mm² 7.8 43.4 80
10 × 2 × 0.14 mm² 8.9 50.6 100
12 × 2 × 0.14 mm² 9.7 58.2 111
16 × 2 × 0.14 mm² 10.5 71.4 136
18 × 2 × 0.14 mm² 11.1 92.8 159
20 × 2 × 0.14 mm² 11.1 98.1 164
24 × 2 × 0.14 mm² 12.8 114.8 203
25 × 2 × 0.14 mm² 12.8 117.5 207
28 × 2 × 0.14 mm² 13.1 125.7 221
30 × 2 × 0.14 mm² 13.8 135.6 237
36 × 2 × 0.14 mm² 14.6 157.3 275
40 × 2 × 0.14 mm² 14.9 168.2 296
44 × 2 × 0.14 mm² 16.3 205.9 348
52 × 2 × 0.14 mm² 17.0 228.1 388
61 × 2 × 0.14 mm² 18.3 263.2 443
2 × 2 × 0.25 mm² 5.7 24.9 42
3 × 2 × 0.25 mm² 6.4 31.4 55
6 × 2 × 0.25 mm² 7.9 50.7 85
8 × 2 × 0.25 mm² 9.0 62.1 109
10 × 2 × 0.25 mm² 9.8 73.9 132
12 × 2 × 0.25 mm² 10.9 101.9 160
16 × 2 × 0.25 mm² 11.9 126.8 195
18 × 2 × 0.25 mm² 12.7 136.6 222
24 × 2 × 0.25 mm² 14.2 170.3 270
2 × 2 × 0.34 mm² 6.8 31.5 57
3 × 2 × 0.34 mm² 7.4 39.7 72
4 × 2 × 0.34 mm² 8.8 49.8 99
5 × 2 × 0.34 mm² 9.5 58.5 116
6 × 2 × 0.34 mm² 9.7 65.1 128
8 × 2 × 0.34 mm² 10.6 80.7 144
12 × 2 × 0.34 mm² 13.4 133.1 225
16 × 2 × 0.34 mm² 14.6 165.0 280
18 × 2 × 0.34 mm² 15.1 178.3 306
24 × 2 × 0.34 mm² 17.6 255.1 415
2 × 2 × 0.50 mm² 7.2 39.3 66
3 × 2 × 0.50 mm² 7.9 50.1 84
6 × 2 × 0.50 mm² 10.4 86.0 146
8 × 2 × 0.50 mm² 10.9 111.5 166
10 × 2 × 0.50 mm² 13.2 146.5 229
12 × 2 × 0.50 mm² 14.4 175.7 268
16 × 2 × 0.50 mm² 16.3 241.3 368
18 × 2 × 0.50 mm² 16.9 261.0 399
20 × 2 × 0.50 mm² 16.9 280.2 418
24 × 2 × 0.50 mm² 19.0 330.4 491
2 × 2 × 0.75 mm² 8.5 52.4 92
3 × 2 × 0.75 mm² 9.4 69.4 112
6 × 2 × 0.75 mm² 12.5 136.5 218
12 × 2 × 0.75 mm² 17.1 261.2 385
16 × 2 × 0.75 mm² 18.6 329.9 482
18 × 2 × 0.75 mm² 19.3 369.3 535
24 × 2 × 0.75 mm² 21.8 469.2 661

Other pair configurations, conductor sizes, sheath colours and customized dimensions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top