Halogen-Free Silicone Twin Cable 300/300 V – Heat Resistant
This halogen-free silicone twin cable is designed for electrical wiring exposed to high temperatures and demanding industrial conditions. It combines heat resistance, low-temperature flexibility, flame-retardant performance and excellent weather resistance for reliable operation in industrial equipment, lamps and heating appliances.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
This heat-resistant silicone twin cable is suitable for installations requiring dependable performance at elevated temperatures and flexibility under cold conditions.
Typical applications include:
- Smelting plants and steelworks
- Hot-rolling mills
- Cement production equipment
- Glass and ceramic manufacturing machinery
- Internal wiring of industrial lamps
- Heating appliances and heating equipment
- High-temperature electrical devices
- Industrial control and power wiring
Conductor: Fine-stranded tinned copper conductors according to IEC 60228 and VDE 0295, Class 5
Insulation: Halogen-free, heat-resistant silicone compound type EI2 according to EN 50363-1 and VDE 0207-363-1
Cable configuration: Two parallel insulated conductors in a flat twin-cable construction
Standard colour: Reddish brown, similar to RAL 3016
Customized conductor sizes, insulation colours and dimensions are available upon request.
Nominal voltage: U₀/U 300/300 V
Testing voltage: 1,500 V
Minimum bending radius: 5 × cable diameter
Temperature range for fixed installation: −40°C to +180°C
Temperature range for flexible application: −25°C to +180°C
Maximum short-time temperature: +250°C
Radiation resistance: Up to 2 × 10⁷ cJ/kg
Halogen-free performance: According to IEC 60754-1 and VDE 0482-754-1
Flame performance: Flame-retardant and self-extinguishing according to IEC 60332-1-2 and VDE 0482-332-1-2
Corrosiveness of combustion gases: According to IEC 60754-2 and VDE 0482-754-2
Weather resistance: Very good
Chemical resistance: Dependent on the chemical medium, concentration, temperature and exposure duration
Restricted substances: Designed in accordance with applicable EU RoHS requirements
PFAS: PFAS-free construction
| Number of Cores × Cross-Section | Largest Single Wire Ø | Approx. Cable Dimensions | Copper Weight | Approx. Cable Weight |
| 2 × 0.50 mm² | 0.21 mm | 4.2 × 2.1 mm | 9.6 kg/km | 17 kg/km |
| 2 × 0.75 mm² | 0.21 mm | 4.8 × 2.4 mm | 14.4 kg/km | 23 kg/km |
Other conductor sizes, colours and customized cable dimensions are available upon request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity