Halogen-Free Screened Marine Control Cable 300/500 V

This halogen-free flexible marine control cable features an overall tinned copper braid for reliable protection against electromagnetic interference. Rated at 300/500 V, it combines good EMC performance with flexible handling, compact dimensions and an SHF1 low-smoke outer sheath for protected shipboard installations.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Designed for control, switching and auxiliary circuits aboard ships where electromagnetic compatibility is required.

Typical applications include:

  • Marine automation and control systems
  • Shipboard control panels
  • EMC-sensitive switching circuits
  • Engine-room monitoring equipment
  • Navigation and communication equipment
  • Sensors, actuators and auxiliary machinery
  • Protected installations above or below deck

The cable should not remain in permanent contact with oils or fuels unless a suitable oil-resistant construction has been specified.

Conductor: Fine-stranded tinned copper, Class 5 according to IEC 60228/VDE 0295

Core insulation: Special halogen-free compound

Core identification: Black cores with consecutive numbers according to EN 50334

Protective conductor: Green-yellow earth conductor included from three-core configurations

Core arrangement: Cores stranded together in layers

Inner wrapping: Foil

Overall screen: Tinned copper braid

Outer sheath: Halogen-free SHF1 compound according to IEC 60092-360

Standard sheath color: Pigeon blue, similar to RAL 5014

Optional construction: Bare copper conductors, alternative core identification and customized sheath colors available on request

Nominal voltage: U₀/U 300/500 V

Test voltage:

  • Core-to-core: 2000 V
  • Core-to-screen: 2000 V

Minimum bending radius:

  • Fixed installation: 5 × cable diameter
  • Flexible application: 10 × cable diameter

Temperature range:

  • Fixed installation: −40°C to +90°C
  • Flexible application: −30°C to +90°C

Conductor class: IEC 60228 Class 5

Halogen-free performance: IEC 60754-1

Flame propagation: IEC 60332-3-22, Category A

Flame retardancy: IEC 60332-1-2

Corrosiveness of combustion gases: IEC 60754-2

Smoke density: IEC 61034

Outer sheath standard: IEC 60092-360 SHF1

Environmental compliance: RoHS-compatible materials

Marine approval, PFAS-free formulation and project-specific certification requirements are subject to confirmation.

Representative standard configurations:

Number of Cores × Cross-Section Approx. Outer Diameter Copper Weight Approx. Cable Weight
2 × 0.50 mm² 5.8 mm 25.5 kg/km 50 kg/km
18 × 0.50 mm² 12.3 mm 140.7 kg/km 251 kg/km
2 × 0.75 mm² 6.4 mm 30.5 kg/km 58 kg/km
18 × 0.75 mm² 13.7 mm 189.4 kg/km 311 kg/km
2 × 1.00 mm² 6.6 mm 36.9 kg/km 65 kg/km
18 × 1.00 mm² 14.6 mm 258.5 kg/km 378 kg/km
2 × 1.50 mm² 7.3 mm 48.5 kg/km 80 kg/km
18 × 1.50 mm² 16.3 mm 357.1 kg/km 488 kg/km
2 × 2.50 mm² 8.7 mm 71.8 kg/km 115 kg/km
18 × 2.50 mm² 20.1 mm 556.3 kg/km 753 kg/km

Outer diameters are subject to a tolerance of approximately ±10%. The copper weight includes the conductors and overall copper screen.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top