Continuously Flexible Halogen-Free PUR Drag Chain Control Cable 300/500 V
This continuously flexible 300/500 V halogen-free PUR control cable is engineered for drag chains and high-dynamic industrial equipment. Its Class 6 conductors, numbered cores, compact outer diameter and small bending radius support reliable installation in confined spaces. The abrasion-resistant PUR jacket provides strong resistance to oil, chemicals, ozone, sunlight and mechanical stress.
Key Highlights
300/500 V rated · Continuously flexible for drag chains · Halogen-free core insulation · Class 6 conductors · Numbered cores · Abrasion-resistant PUR jacket · Low capacitance · Compact outer diameter · 7.5 × d dynamic bending radius · Oil and chemical resistant · Flexible down to -40°C in moving applications · UV and ozone resistant · PWIS-uncritical · PFAS-free · RoHS compliant
- Application
- Construction
- Technical Data
- Dimensions
- Packaging
This flexible control cable is designed for high-cycle linear movement and space-restricted industrial installations.
Typical applications include:
- Drag chains and energy chain systems
- Automated production and assembly equipment
- CNC machines and moving machine-tool components
- Packaging and processing machinery
- Conveyor and material-handling systems
- Linear robot axes and robotic peripheral equipment
- Short-travel applications with frequent bending cycles
- Paint shops requiring PWIS-uncritical materials
- Industrial environments exposed to oil, chemicals, hydraulic fluids, ozone or sunlight
Its low-temperature flexibility makes it suitable for demanding indoor and outdoor motion applications.
The cable construction is specified below.
| Component | Description |
| Conductor | Bare copper strands in accordance with IEC 60228 and VDE 0295, Class 6 |
| Core insulation | Halogen-free insulation compound |
| Core identification | Black cores with consecutive numbers in accordance with EN 50334 and VDE 0293-334 |
| Protective conductor | Green/yellow earth conductor from three cores |
| Core stranding | Specially optimized layer construction with nonwoven tape over each layer |
| Overall wrapping | Nonwoven tape |
| Shielding | Unshielded |
| Outer sheath | Matte PUR/TMPU compound in accordance with EN 50363-10-2 and VDE 0207-363-10-2 |
| Sheath color | Black, similar to RAL 9005 |
The principal electrical, mechanical and environmental characteristics are specified below.
| Parameter | Value |
| Nominal voltage | U₀/U 300/500 V |
| Testing voltage | 2000 V, core to core |
| Torsion angle | ±60° per 1 m |
| Minimum bending radius | Fixed installation: 3 × cable diameter; continuous-flex application: 7.5 × cable diameter |
| Temperature range | Fixed installation: -50°C to +90°C; continuous-flex application: -40°C to +90°C |
| Multicore conductor sizes | 0.50–50.0 mm² |
| Single-conductor sizes | Up to 300.0 mm² |
| Available conductor count | 1–65 conductors |
| Halogen-free performance | In accordance with IEC 60754-1 and VDE 0482-754-1 |
| Oil resistance | Very good; TMPU in accordance with EN 50363-10-2 and VDE 0207-363-10-2 |
| Chemical resistance | Good resistance to acids, alkalis, solvents, hydraulic fluids and similar industrial media |
| Continuous-flex performance | Very good |
| Sunlight resistance | In accordance with HD 605 |
| Ozone resistance | In accordance with DIN EN 50396 |
| Salt-water resistance | In accordance with UL 1309 |
| Restricted substances | RoHS compliant and PFAS-free |
| PWIS compatibility | PWIS-uncritical |
Standard dimensional data is listed below. Values marked † must be replaced with Hulk’s verified production data before publication because the source webpage and datasheet differ.
| Core Configuration | Largest Single Wire Diameter | Approx. Outer Diameter ±10% | Copper Weight | Approx. Cable Weight |
| 5 × 0.50 mm² | 0.16 mm | 5.4 mm | 24.0 kg/km | 43 kg/km |
| 7 × 0.50 mm² | 0.16 mm | 6.4 mm | 33.6 kg/km | 60 kg/km |
| 12 × 0.50 mm² | 0.16 mm | 7.6 mm | 57.6 kg/km | 86 kg/km |
| 18 × 0.50 mm² | 0.16 mm | 9.0 mm | 86.4 kg/km | 123 kg/km |
| 25 × 0.50 mm² | 0.16 mm | 11.0 mm | 120.0 kg/km | 173 kg/km |
| 2 × 0.75 mm² | 0.16 mm | 4.9 mm | 14.4 kg/km | 30 kg/km |
| 3 × 0.75 mm² | 0.16 mm | 5.2 mm | 21.6 kg/km | 37 kg/km |
| 4 × 0.75 mm² | 0.16 mm | 5.6 mm | 28.8 kg/km | 48 kg/km |
| 5 × 0.75 mm² | 0.16 mm | 6.1 mm | 36.0 kg/km | 63 kg/km |
| 7 × 0.75 mm² | 0.16 mm | 7.1 mm | 50.4 kg/km | 78 kg/km |
| 18 × 0.75 mm² | 0.16 mm | 10.6 mm | 129.6 kg/km | 184 kg/km |
| 2 × 1.00 mm² | 0.16 mm | 5.1 mm | 19.2 kg/km | 35 kg/km |
| 7 × 1.00 mm² | 0.16 mm | 7.6 mm | 67.2 kg/km | 98 kg/km |
| 12 × 1.00 mm² | 0.16 mm | 9.1 mm | 115.2 kg/km | 146 kg/km |
| 18 × 1.00 mm² | 0.16 mm | 11.0 mm | 172.8 kg/km | 226 kg/km |
| 25 × 1.00 mm² | 0.16 mm | 13.2 mm | 240.0 kg/km | 297 kg/km |
| 2 × 1.50 mm² | 0.16 mm | 5.7 mm | 28.8 kg/km | 47 kg/km |
| 3 × 1.50 mm² | 0.16 mm | 6.0 mm | 43.2 kg/km | 63 kg/km |
| 4 × 1.50 mm² | 0.16 mm | 6.5 mm | 57.6 kg/km | 78 kg/km |
| 5 × 1.50 mm² | 0.16 mm | 7.3 mm | 72.0 kg/km | 99 kg/km† |
| 7 × 1.50 mm² | 0.16 mm | 8.5 mm | 100.8 kg/km | 139 kg/km† |
| 12 × 1.50 mm² | 0.16 mm | 10.7 mm | 172.8 kg/km | 213 kg/km |
| 25 × 1.50 mm² | 0.16 mm | 15.4 mm | 360.0 kg/km | 432 kg/km |
| 2 × 2.50 mm² | 0.16 mm | 6.7 mm | 48.0 kg/km | 67 kg/km |
| 3 × 2.50 mm² | 0.16 mm | 7.5 mm | 72.0 kg/km | 97 kg/km |
| 4 × 2.50 mm² | 0.16 mm | 8.3 mm | 96.0 kg/km | 125 kg/km |
| 5 × 2.50 mm² | 0.16 mm | 8.5 mm† | 120.0 kg/km | 140 kg/km |
| 3 × 6.00 mm² | 0.21 mm | 10.9 mm | 172.8 kg/km | 223 kg/km |
| 5 × 6.00 mm² | 0.21 mm | 13.2 mm | 288.0 kg/km | 351 kg/km |
| 3 × 10.0 mm² | 0.21 mm | 13.6 mm† | 288.0 kg/km | 394 kg/km† |
| 1 × 16.0 mm² | 0.21 mm | 7.9 mm | 153.6 kg/km | 169 kg/km |
| 1 × 25.0 mm² | 0.21 mm | 9.3 mm | 240.0 kg/km | 250 kg/km |
| 1 × 35.0 mm² | 0.21 mm | 11.1 mm | 336.0 kg/km | 356 kg/km |
One additional 1.00 mm² configuration in the source contains an unresolved core-count discrepancy and has therefore been omitted. Other conductor sizes, core configurations, sheath colors and customized dimensions are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
SEND US YOUR
SPECIFICATION
Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.
Your information is used only to prepare your quotation and is never shared with third parties.
RELATED SERIES
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen jacket with numbered cores for fast identification during panel wiring and maintenance.
View Product →
Halogen-Free Single Conductor Wiring Cable 450/750 V
Extended temperature range for control cabinet and switchgear wiring where flame behaviour is critical.
View Product →
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen construction with braid screening for reliable EMC performance in dense cabinets.
View Product →
Halogen-Free Single Conductor Wiring Cable 600 V UL
Flame retardant and UL recognised for North American panel builds and export-bound equipment.
View Product →