Continuously Flexible Halogen-Free Outdoor Rail Cable
This continuously flexible halogen-free rail cable is designed for moving equipment operating inside and outside railway vehicles. Its cross-linked construction provides excellent resistance to weather, UV radiation, ozone, oil and fuel while supporting demanding railway fire-safety requirements.
Key Highlights
Suitable for indoor and outdoor railway use · Continuously flexible · Torsion resistant · 300/500 V and 0.6/1 kV options · Unscreened and screened versions · Paired constructions available · UV, ozone and weather resistant · Oil and fuel resistant · EN 45545-2 HL1–HL3 · UN/ECE R118 flame retardancy · Halogen-free · Low smoke · PFAS-free option
- Application
- Construction
- Technical Data
- Dimensions
- Packaging
Suitable for railway bogies, external moving equipment, railway construction machinery, door systems and other indoor or outdoor railway applications involving continuous movement.
Unscreened, overall-screened and paired-screened versions are available for power, control and signal transmission. Selected constructions are available with 300/500 V or 0.6/1 kV ratings.
Conductor: Extra-fine tinned copper strands
Core insulation: Cross-linked halogen-free insulation compound
Core identification: Black cores with consecutive numbers according to EN 50334 and VDE 0293-334
Protective conductor: Green-yellow earth core included from three-core constructions
Core arrangement: Cores stranded in layers or twisted in pairs
Inner wrapping: Protective foil
Optional screen: Tinned copper wire braid
Outer sheath: Cross-linked halogen-free compound
Standard sheath color: Black, similar to RAL 9005
Nominal voltage:
Standard versions: U₀/U 300/500 V
Power versions: U₀/U 0.6/1 kV
Testing voltage for 300/500 V versions:
Core to core: 2000 V
Core to screen: 2000 V
Testing voltage for 0.6/1 kV versions:
Core to core: 4000 V
Core to screen: 4000 V
Minimum bending radius:
Fixed installation: 4 × cable diameter
Flexible use: 6 × cable diameter
Continuous flex: 10 × cable diameter
Torsion angle: ±15° per metre
Temperature range:
Fixed installation: −50°C to +90°C
Flexible use: −50°C to +90°C
Fire protection: EN 45545-2, requirement sets R15 (EL1A) and R16 (EL1B), Hazard Levels HL1–HL3
Flame propagation: IEC 60332-3-24, IEC 60332-3-25 and EN 50305 Section 9.1.2
Flame retardancy: IEC 60332-1-2 and ISO 6722 / UN/ECE R118
Halogen-free requirements: EN 50306-1 and EN 50264-1
Hydrogen chloride content: Less than 0.5% according to IEC 60754-1
Combustion gas pH value: Greater than 4.3 according to IEC 60754-2
Conductivity: Less than 10 µS/mm according to IEC 60754-2
Fluorine content: Less than 0.1% according to IEC 60684-2
Toxicity: EN 50305
Smoke density: IEC 61034
Oil and fuel resistance: EN 50264-1
Weather resistance: Very good
Environmental compliance: RoHS compliant; PFAS-free material formulation available
Available conductor size range: 0.25–35.00 mm²
Available constructions: Unscreened, overall-screened and paired-screened versions
Approximate overall diameter range: 5.3–34.1 mm
| Construction | Cable Configuration | Voltage | Approx. Outer Diameter | Copper Weight | Approx. Cable Weight |
| Unscreened | 2 × 0.50 mm² | 300/500 V | 5.3 mm | 9.6 kg/km | 40 kg/km |
| Unscreened | 5 × 0.75 mm² | 300/500 V | 6.4 mm | 36.0 kg/km | 73 kg/km |
| Unscreened | 7 × 1.00 mm² | 300/500 V | 7.9 mm | 67.2 kg/km | 127 kg/km |
| Unscreened | 25 × 1.00 mm² | 300/500 V | 13.4 mm | 240.0 kg/km | 346 kg/km |
| Unscreened | 7 × 1.50 mm² | 300/500 V | 9.3 mm | 100.8 kg/km | 175 kg/km |
| Unscreened | 5 × 35.00 mm² | 0.6/1 kV | 33.2 mm | 1680.0 kg/km | 2299 kg/km |
| Screened | 2 × 0.50 mm² | 300/500 V | 5.3 mm | 24.7 kg/km | 42 kg/km |
| Screened | 12 × 0.50 mm² | 300/500 V | 8.5 mm | 85.9 kg/km | 132 kg/km |
| Screened | 13 × 1.00 mm² | 300/500 V | 10.8 mm | 169.2 kg/km | 235 kg/km |
| Screened | 7 × 1.50 mm² | 300/500 V | 9.7 mm | 127.4 kg/km | 195 kg/km |
| Screened | 5 × 35.00 mm² | 0.6/1 kV | 34.1 mm | 1885.3 kg/km | 2455 kg/km |
| Paired and screened | 6 × 2 × 0.25 mm² | 300/500 V | 8.0 mm | 46.3 kg/km | 98 kg/km |
| Paired and screened | 12 × 2 × 0.34 mm² | 300/500 V | 11.9 mm | 131.4 kg/km | 204 kg/km |
| Paired and screened | 2 × 2 × 0.50 mm² | 300/500 V | 6.7 mm | 35.5 kg/km | 69 kg/km |
| Paired and screened | 8 × 2 × 0.50 mm² | 300/500 V | 12.3 mm | 129.3 kg/km | 230 kg/km |
| Paired and screened | 3 × 2 × 0.75 mm² | 300/500 V | 8.4 mm | 65.9 kg/km | 124 kg/km |
Additional conductor sizes, voltage ratings, core counts, pair configurations and customized dimensions are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
SEND US YOUR
SPECIFICATION
Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.
Your information is used only to prepare your quotation and is never shared with third parties.
RELATED SERIES
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen jacket with numbered cores for fast identification during panel wiring and maintenance.
View Product →
Halogen-Free Single Conductor Wiring Cable 450/750 V
Extended temperature range for control cabinet and switchgear wiring where flame behaviour is critical.
View Product →
Halogen-Free Screened Control Cable with Numbered Cores
Low smoke zero halogen construction with braid screening for reliable EMC performance in dense cabinets.
View Product →
Halogen-Free Single Conductor Wiring Cable 600 V UL
Flame retardant and UL recognised for North American panel builds and export-bound equipment.
View Product →