CAT 6A Industrial Ethernet Reeling Cable
This CAT 6A Ethernet cable is engineered for repeated winding on industrial cable reels. Its reinforced PUR sheath system, mechanical supporting braid and overall foil-and-copper screen provide reliable data transmission under demanding mechanical, weather and oil exposure.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
Recommended for reel-operated industrial Ethernet connections.
Typical applications include:
- Stage and theatre equipment
- Mobile screen-cleaning systems
- High-bay warehouses
- Construction machinery
- Mobile handling equipment
- Reel-operated industrial cameras
- Automated storage systems
- EtherCAT and EtherNet/IP-compatible networks
Reel diameter, cable length, tensile load and pulley geometry must be confirmed for each installation.
| Component | Construction |
| Standard configuration | 4 × 2 × 26 AWG |
| Conductor | Fine-stranded bare copper |
| Core insulation | Special polymer compound |
| Core identification | Standard Ethernet pair colors |
| Pair formation | Four individually twisted pairs |
| Overall stranding | Pairs stranded together |
| Inner wrapping | Nonwoven tape |
| Overall screen | Aluminum-laminated foil and tinned-copper braid |
| Screen wrapping | Nonwoven tape |
| Sheath system | PUR inner layer, mechanical supporting braid and PUR outer sheath |
| Standard sheath color | Black, similar to RAL 9005 |
| Property | Reference Value |
| Maximum operating voltage | 90 V |
| Test voltage, core to core | 750 V |
| Test voltage, core to screen | 750 V |
| Characteristic impedance at 100 MHz | 100 Ω ±10 Ω |
| Transmission category | CAT 6A |
| Transmission standard reference | EN 50288-10-2 |
| Minimum bending radius, fixed | 5 × cable diameter |
| Minimum bending radius, repeated winding | 10 × cable diameter |
| Minimum bending radius, pulley-guided | 12 × cable diameter |
| Temperature range, fixed | −50°C to +90°C |
| Temperature range, flexible | −40°C to +90°C |
| Halogen-free performance | According to IEC 60754-1 |
| Oil resistance | According to EN 50363-10-2 |
| Weather resistance | Very good |
| Maximum tensile load | 200 N |
| Network compatibility | Suitable for EtherCAT and EtherNet/IP applications |
| Compliance options | RoHS-compliant and PFAS-free materials, subject to confirmation |
| Configuration | Maximum Core Ø | Approx. Outer Ø | Copper Weight | Approx. Cable Weight | Maximum Tensile Load |
| 4 × 2 × 26 AWG | 1.05 mm | 8.7 mm | 32 kg/km | 81 kg/km | 200 N |
Outer diameter tolerance: Approximately ±10%
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity