Continuous-Flex Single Pair Ethernet Cable for Drag Chains

A shielded Single Pair Ethernet cable design for repeated bending in drag chains. The reference uses one twisted copper pair, an overall foil and braid screen, and a green halogen-free PUR jacket. The 26 AWG and 22 AWG versions have nominal diameters of 4.6 mm and 5.7 mm, respectively.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

This construction suits a link from a fixed controller to an SPE sensor or I/O module on a moving carriage. Check the carrier radius, space at the cable exit, and the cable entry of the selected SPE connector. If the device also receives power over the data pair, verify the power class and available power at the installed length. High-flex industrial Ethernet cables for drag chains

Component Reference specification
Conductors Stranded bare copper, 26 AWG with 7 strands or 22 AWG with 19 strands
Insulation Special polymer
Core identification White and blue
Core lay One twisted pair
Inner sheath SABIX compound in the reference design
Overall screen Aluminum foil and tinned copper braid
Wrap over screen Nonwoven tape
Outer jacket Green PUR, similar to RAL 6018
Property Reference value
Peak operating voltage 90 V max.
Dielectric test voltage 2,000 V core to core and core to screen
Minimum bend radius 5 × cable OD fixed, 10 × flexible, 15 × under continuous flexing
Temperature range −40 to +70 °C for fixed and flexible use
Characteristic impedance 100 ± 10 Ω
Transmission reference 1–600 MHz with reference to IEC 61156-12
Data transmission listed by SAB 1 Gbit/s up to 40 m
Power over Data Lines (PoDL) SAB cites up to approximately 50 W at 48 V DC. Available power depends on the complete link.
Halogen test reference IEC 60754-1 and VDE 0482-754-1
Flame test references IEC 60332-1-2, VDE 0482-332-1-2, and FT2
Oil resistance reference TMPU per EN 50363-10-2 and VDE 0207-363-10-2
Other properties listed by SAB Resistance to aggressive chemicals and suitability for applications sensitive to paint-wetting impairment substances (PWIS)
SAB AWM marking UL AWM Style 20549, 300 V and 80 °C
SAB material declarations EU RoHS conformity and PFAS-free designation
SAB item no. Cable size Cable OD ±10% Copper figure Approx. weight Min. continuous-flex bend radius at nominal OD
L17771630 2 × 26/7 AWG 4.6 mm 16.9 kg/km 29 kg/km 69 mm
L17771230 2 × 22/19 AWG 5.7 mm 22.7 kg/km 40 kg/km 85.5 mm

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top