Screened Halogen-Free PUR PROFINET Type C Continuous-Flex Cable

A screened, halogen-free PUR PROFINET Type C cable design for continuous bending in drag chains. The reference comes in a seven-strand Fast Connect construction and a 19-strand construction for more demanding bending duty. Both use two 22 AWG pairs and have a nominal cable diameter of 6.5 mm.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

This construction suits a guided Ethernet link from a fixed control cabinet to a moving gantry or transfer carriage. Check the cable carrier’s bend radius and the clearance at its exit throughout the travel. When specifying field termination, match the connector contacts to the selected conductor stranding and the strain relief to the cable diameter. High-flex industrial Ethernet cables for drag chains

Component Reference specification
Cable configuration 2 × 2 × 22 AWG
Conductors Tinned copper, 7 or 19 strands per conductor depending on the item
Insulation Special polymer
Core identification Blue, yellow, white, and orange
Core lay and wrap Cores laid in layers with PETP polyester film wrap
Inner sheath Thermoplastic
Overall screen Aluminum foil and tinned copper braid
Wrap over screen Nonwoven tape
Outer jacket Green PUR, similar to RAL 6018
Property Reference value
Peak operating voltage 350 V max.
Dielectric test voltage 2,000 V core to core and core to screen
Minimum bend radius 5 × cable OD fixed, 10 × flexible, 15 × under continuous flexing
Temperature range −40 to +70 °C for fixed and flexible installation
Characteristic impedance 100 ± 5 Ω
Transmission reference EN 50288-2-2 and VDE 0819-2-2, CAT 5 per EN 50173
Network applications listed by SAB PROFINET, EtherCAT, and EtherNet/IP
Halogen test reference IEC 60754-1 and VDE 0482-754-1
Oil resistance reference TMPU per EN 50363-10-2 and VDE 0207-363-10-2
SAB marking example for L06672202 UL AWM Style 21198 and CSA AWM I/II A/B, 300 V and 80 °C. The marking also includes FT2.
SAB material declarations EU RoHS conformity and PFAS-free designation
SAB item no. Cable size Strands per conductor Max. insulated core OD Cable OD ±10% Copper figure Approx. weight Max. DC resistance at 20 °C per VDE 0812
L06672202 2 × 2 × 22 AWG 7 1.55 mm 6.5 mm 33.8 kg/km 60 kg/km 58.8 Ω/km
L06679001 2 × 2 × 22 AWG 19 1.55 mm 6.5 mm 33.8 kg/km 58 kg/km 58.8 Ω/km

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity