Compact Screened Flexible PVC Tray Cable 600 V

This compact screened tray and machine-tool cable uses a PETP foil wrapping and overall tinned-copper braid to achieve a smaller finished diameter than a conventional inner-sheath design. It combines EMC protection with oil, sunlight and industrial-environment resistance.

Key Highlights

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Suitable for industrial installations where installation space, cable weight and electromagnetic compatibility are important.

Typical applications include:

  • Compact machine tools
  • Control cabinets with limited cable-entry space
  • CNC and automated production equipment
  • Assembly and packaging lines
  • Control-panel-to-machine connections
  • Cable trays and machinery areas
  • Circuits installed near motors and drives

Conductor: Fine-stranded bare copper based on Class 5 reference requirements

Core insulation: Special PVC/Nylon compound

Core identification: Black cores with numbers

Protective conductor: Green/yellow core from three-core versions where required

Stranding: Cores stranded in layers

Wrapping: PETP foil

Overall screen: Tinned-copper wire braid

Outer sheath: Sunlight- and oil-resistant PVC

Sheath color: Black, similar to RAL 9005

Reference voltage: 600 V for UL AWM, Type TC and cUL applications; 1000 V WTTC reference rating

Test voltage:

  • AWG 18–10: 6000 V
  • AWG 8–2: 7500 V

Minimum bending radius: 5 × D fixed and 10 × D flexible

Temperature references: Up to +105°C under UL AWM; up to +90°C under UL/cUL; fixed installation down to −25°C under UL AWM reference

Reference flame performance: UL FT4 and cUL FT1, FT2 and FT4

Oil resistance: Oil Resistance I reference

Additional properties: Sunlight resistant, Exposed Run, Direct Burial and Machinery Area references

Radiation resistance: Approximately 8 × 10⁷ cJ/kg

Design references: TC-ER, MTW, WTTC, AWM Style 21179, shielded cUL Type CIC and NFPA 79

Cores × Size Largest Wire Ø Approx. Outer Ø Copper Weight Approx. Cable Weight
3 × 16 AWG 0.26 mm 8.8 mm 66.9 kg/km 109 kg/km
12 × 16 AWG 0.26 mm 15.4 mm 269.7 kg/km 369 kg/km
4 × 14 AWG 0.26 mm 10.5 mm 125.2 kg/km 175 kg/km
4 × 12 AWG 0.31 mm 12.1 mm 207.8 kg/km 256 kg/km
4 × 8 AWG 0.41 mm 19.0 mm 461.3 kg/km 619 kg/km

Outer-diameter tolerance: Approximately ±10%

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Engineering Support for Your Application

Tell Us How Your Cable Needs to Move

Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.

  • 01 Motion type, travel distance and minimum bend radius
  • 02 Voltage, current, signal protocol and shielding needs
  • 03 Operating environment, target service life and quantity
You May Also Need

RELATED SERIES

View All Products
Scroll to Top