Screened PVC PROFINET Type A Fixed-Installation Cable

This PROFINET Type A cable is designed for fixed Industrial Ethernet installation in machinery, control cabinets and factory networks. Bare copper conductors, PE insulation, an overall tinned-copper braid and a durable PVC sheath provide compact and reliable CAT 5 data transmission where repeated movement is not required.

Key Highlights

PROFINET Type A · Fixed-installation construction · CAT 5 transmission · Bare copper conductors · Compact 5.3 mm reference diameter · Tinned-copper braid · PVC outer sheath · 100 Ω characteristic impedance · Suitable for control cabinets and fixed machine wiring · EtherCAT and EtherNet/IP compatibility · Optional M12 or RJ45 assemblies · PFAS-free material option

Recommended for permanently installed PROFINET and Industrial Ethernet networks.

Typical applications include:

  • Fixed machine wiring
  • Control cabinets
  • Factory automation networks
  • Production equipment
  • Industrial communication infrastructure
  • Building and plant automation
  • Fixed connections between control devices
  • Sensors and monitoring systems
  • EtherCAT networks
  • EtherNet/IP networks

This Type A cable is intended primarily for fixed installation. It should not be selected for recurring movement, drag chains or torsional applications.

Pre-assembled M12 and RJ45 versions are available on request.

Cable configuration: 2 × 2 × 22 AWG

Conductor: Bare copper wire

Core insulation: PE L/MD according to EN 50290-2-23

Core identification: Blue, yellow, white and orange

Stranding: Cores arranged in layers

Core wrapping: PETP foil

Overall screen: Tinned-copper wire braid

Outer sheath: PVC

Standard sheath color: Green, similar to RAL 6018

Cable shape: Round

PROFINET classification: Type A

Installation type: Fixed installation

Transmission category: CAT 5

Peak operating voltage: Maximum 350 V

Test voltage:

  • Core to core: 1500 V
  • Core to screen: 1200 V

Characteristic impedance: 100 Ω ±5 Ω

Transmission references:

  • EN 50288-2-2
  • VDE 0819-2-2
  • CAT 5 according to EN 50173-1

Minimum bending radius:

  • Fixed installation: 5 × cable diameter

Reference temperature range:

  • Fixed installation: −30°C to +70°C
  • Material reference for occasional movement: −5°C to +70°C

Maximum conductor resistance at 20°C: 54.1 Ω/km according to VDE 0812 reference requirements

Oil resistance: Reference performance according to the applicable internal material test

Network compatibility reference: Suitable for PROFINET, EtherCAT and EtherNet/IP applications

Environmental compliance reference: RoHS and PFAS-free material options

Cable Configuration Maximum Insulated Core Ø Approx. Outer Ø Copper Weight Approx. Cable Weight Maximum Conductor Resistance
2 × 2 × 22 AWG 1.55 mm 5.3 mm 28.0 kg/km 43 kg/km 54.1 Ω/km

Final outer-diameter tolerance must be confirmed against the approved production drawing. Other sheath colors, dimensions and connector assemblies are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top