Low-Smoke Halogen-Free CAT 5e Marine Ethernet Cable
This screened CAT 5e Industrial Ethernet cable is designed for data communication in ships, marine equipment and onboard automation systems. Its fine-stranded conductors, star-quad or twisted-pair construction, combined foil-and-braid screen and low-smoke halogen-free sheath provide reliable signal transmission and enhanced fire performance in demanding maritime environments.
Key Highlights
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
- Application
- Construction
- Technical data
- Dimensions
- Packaging
Recommended for industrial Ethernet and data connections in shipbuilding and marine equipment.
Typical applications include:
- Shipboard communication networks
- Vessel automation systems
- Bridge and control-room equipment
- Machinery monitoring systems
- Passenger information systems
- Onboard surveillance equipment
- Marine diagnostic interfaces
- EtherCAT and EtherNet/IP networks
- Data connections between shipboard control cabinets
- Protected installations inside vessels and marine equipment
The cable is suitable for fixed installation and occasional flexible movement. It is not intended for continuous drag-chain, torsional or subsea applications unless a separately tested construction is specified.
Pre-assembled versions with M12 or RJ45 connectors are available on request.
Conductor: Fine-stranded bare copper
Core insulation: Special polymer compound
Core identification:
- Two-pair versions: Blue, yellow, white and orange
- Four-pair version: White-blue/blue, white-orange/orange, white-green/green and white-brown/brown
Data-element formation:
- Two-pair versions: Star-quad construction
- Four-pair version: Individual cores twisted into pairs, with pairs laid together
Overall screen: Aluminium-laminated foil and tinned-copper wire braid
Outer sheath: Special low-smoke, halogen-free marine compound
Standard sheath color: Black
Cable shape: Round
Product category: CAT 5e Industrial Ethernet cable for marine applications
Peak operating voltage: Maximum 90 V
Reference UL voltage: 300 V
Test voltage:
- Core to core: 2000 V
- Core to screen: 2000 V
Characteristic impedance at 100 MHz:
- Two-pair versions: 100 Ω ±5 Ω
- Four-pair version: 100 Ω ±10 Ω
Transmission reference: EN 50288-2-2 / Category 5 reference requirements
Minimum bending radius:
- Fixed installation: 5 × cable diameter
- Flexible application with seven-wire conductors: 10 × cable diameter
Temperature range:
- Fixed installation: −40°C to +70°C
- Flexible application: −30°C to +70°C
- Reference UL temperature: Up to +75°C
Reference marine standard: TR IEC 60092-370
Reference marine approval: ABS Type Approval
Reference UL construction: UL AWM Style 21080
Halogen-free performance reference: IEC 60754-1
Reference fire performance:
- No flame propagation according to IEC 60332-3-22, Category A
- Flame-retardant and self-extinguishing according to IEC 60332-1-2
- UL Horizontal Flame Test FT2
- Smoke-density reference according to IEC 61034
- Low-corrosivity combustion gases according to IEC 60754-2
Chemical resistance: Good resistance to aggressive chemicals
Network compatibility reference: Suitable for EtherCAT and EtherNet/IP applications
Material reference: Asbestos-free construction
Environmental compliance reference: RoHS and PFAS-free material options
| Pair Configuration | Approx. Outer Ø | Copper Weight | Approx. Cable Weight |
| 2 × 2 × 24/7 AWG | 5.7 mm ±10% | 22.7 kg/km | 48 kg/km |
| 2 × 2 × 22/7 AWG | 6.4 mm ±10% | 29.7 kg/km | 61 kg/km |
| 4 × 2 × 26/7 AWG | 7.3 mm ±10% | 31.9 kg/km | 64 kg/km |
Other conductor sizes, pair configurations, sheath colors and customized cable assemblies are available on request.
THE FACTORY
BEHIND EVERY METER
Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.
Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.
Source Factory
Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.
Deep Customization
Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.
7-Day Sampling
Rapid samples for new specifications. 15-day lead time on standard production orders.
Global Compliance
35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.
BEFORE YOU ORDER
For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.
Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.
Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.
Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.
Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.
Engineering Support for Your Application
Tell Us How Your Cable Needs to Move
Send us a datasheet, drawing, existing cable model or a short description of your application. Our engineering team will help you identify a suitable cable construction.
- 01 Motion type, travel distance and minimum bend radius
- 02 Voltage, current, signal protocol and shielding needs
- 03 Operating environment, target service life and quantity