Halogen-Free Rail Data Cable for EN 45545-2 and NFPA 130

This flexible halogen-free rail data cable is designed for signal and low-voltage data transmission inside railway vehicles. Its lightweight unscreened construction combines good flexibility with low-smoke, flame-retardant and self-extinguishing performance.

Key Highlights

Unscreened rail data cable · Lightweight flexible construction · EN 45545-2 R15 HL1–HL3 · NFPA 130 fire performance · UN/ECE R118 flame retardancy · Low smoke · Halogen-free · No flame propagation · Self-extinguishing · DIN 47100 core identification · RoHS compliant · PFAS-free option

Suitable for the internal wiring of railway vehicles, including control electronics, onboard monitoring systems, passenger information equipment, measuring devices and data circuits that do not require electromagnetic screening.

It is recommended for fixed installation and occasional flexible use in railway environments where reduced smoke, limited flame propagation and non-corrosive combustion gases are important.

Conductor: Flexible bare copper strands based on IEC 60228 and VDE 0295, Class 5

Core insulation: Special halogen-free insulation compound

Core identification: Color coded with reference to DIN 47100

Core arrangement: Cores stranded together in layers

Outer sheath: Special halogen-free compound

Standard sheath color: Grey, similar to RAL 7032

Screen: Unscreened construction

Peak operating voltage:

Below 0.25 mm²: Maximum 350 V

0.25 mm² and above: Maximum 500 V

Testing voltage: 1500 V core to core

Minimum bending radius:

Fixed installation: 5 × cable diameter

Flexible use: 10 × cable diameter

Temperature range:

Fixed installation: −40°C to +90°C

Flexible use: −30°C to +90°C

Railway fire protection: EN 45545-2, requirement set R15 (EL1A), Hazard Levels HL1–HL3

North American railway fire protection: NFPA 130, Sections 8.6.7.1.1.1 and 12.2.1

Flame propagation: IEC 60332-3-24, IEC 60332-3-25 and EN 50305 Section 9.1.2

Flame retardancy: UL 1685 Section 12, FT4/IEEE 1202 and ISO 6722 / UN/ECE R118

Individual cable flame test: IEC 60332-1-2

Toxicity: EN 50305

Smoke density: IEC 61034

Halogen-free requirements: EN 50306-1 and EN 50264-1

Hydrogen chloride content: Less than 0.5% according to IEC 60754-1

Combustion gas pH value: Greater than 4.3 according to IEC 60754-2

Conductivity: Less than 10 µS/mm according to IEC 60754-2

Fluorine content: Less than 0.1% according to IEC 60684-2

Environmental compliance: RoHS compliant; PFAS-free material formulation available

Available conductor size range: 0.14–1.50 mm²

Available core configurations: 2–61 cores, depending on conductor size

Approximate overall diameter range: 3.1–19.8 mm

Cable Configuration Approx. Outer Diameter Copper Weight Approx. Cable Weight
2 × 0.14 mm² 3.1 mm 2.7 kg/km 13 kg/km
12 × 0.14 mm² 5.3 mm 16.1 kg/km 38 kg/km
2 × 0.25 mm² 3.4 mm 4.8 kg/km 17 kg/km
12 × 0.25 mm² 6.1 mm 28.8 kg/km 57 kg/km
2 × 0.34 mm² 4.0 mm 6.5 kg/km 24 kg/km
12 × 0.34 mm² 7.3 mm 39.2 kg/km 80 kg/km
2 × 0.50 mm² 4.3 mm 9.6 kg/km 28 kg/km
12 × 0.50 mm² 8.1 mm 57.6 kg/km 102 kg/km
2 × 0.75 mm² 4.9 mm 14.4 kg/km 38 kg/km
12 × 0.75 mm² 9.4 mm 86.4 kg/km 142 kg/km
2 × 1.00 mm² 5.1 mm 19.2 kg/km 43 kg/km
7 × 1.00 mm² 7.3 mm 67.2 kg/km 104 kg/km
2 × 1.50 mm² 5.6 mm 28.8 kg/km 55 kg/km
7 × 1.50 mm² 8.4 mm 100.8 kg/km 144 kg/km

Additional conductor sizes, core counts, sheath colors and customized dimensions are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top