High-Temperature Silicone Cable for Neon and Tube Lighting

This silicone-insulated single-conductor cable is designed for neon signs, tube lamps and other lighting equipment operating at high or fluctuating temperatures. It combines high-voltage insulation, low-temperature flexibility, flame-retardant performance and a high-visibility yellow outer surface.

Key Highlights

Designed for neon and tube lighting · 3.5 kV, 4.0 kV and 7.5 kV versions · 10 kV test voltage · Heat resistant up to +180°C · Short-time temperature up to +250°C · High-visibility yellow insulation · Flexible at low temperatures · Halogen-free · PFAS-free · Flame-retardant and self-extinguishing · Very good weather resistance · RoHS compliant

Recommended for protected internal installation in high-voltage lighting and tube-lamp systems.

Typical applications include:

  • Neon signs and neon lighting
  • Tube lamps and discharge lamps
  • Floodlights and lighting projectors
  • Industrial lamps
  • Drop lights and suspended lighting
  • Machine and equipment lighting
  • High-temperature illumination systems

Protected installation is required for this single-conductor cable.

Conductor: Class 5 flexible tinned copper strands according to IEC 60228 and VDE 0295
Insulation: EI2 silicone compound according to EN 50363-1 and VDE 0207-363-1
Standard insulation color: Yellow, similar to RAL 1006

Available nominal voltages: U₀ 3.5 kV, U₀ 4.0 kV and U₀ 7.5 kV
Test voltage: 10 kV
Minimum bending radius: 7.5 × cable diameter
Temperature range, fixed installation: −40°C to +180°C
Temperature range, flexible application: −25°C to +180°C
Maximum short-time temperature: +250°C
Radiation resistance: 2 × 10⁷ cJ/kg
Halogen-free: IEC 60754-1 and VDE 0482-754-1
Flame retardant and self-extinguishing: IEC 60332-1-2 and VDE 0482-332-1-2
Combustion gas corrosiveness: No development of corrosive combustion gases according to IEC 60754-2 and VDE 0482-754-2
Chemical resistance: Dependent on the chemical, concentration and operating temperature
Weather resistance: Very good
PFAS status: PFAS-free
Compliance: RoHS

Cross Section Largest Single Wire Ø Nominal Voltage Approx. Outer Ø Copper Weight Approx. Cable Weight
1.50 mm² 0.26 mm U₀ 3.5 kV 4.4 mm 14.4 kg/km 32 kg/km
1.50 mm² 0.26 mm U₀ 4.0 kV 6.6 mm 14.4 kg/km 59 kg/km
1.50 mm² 0.26 mm U₀ 7.5 kV 7.6 mm 14.4 kg/km 75 kg/km

Outer diameter tolerance: ±10%
Other dimensions, voltage levels and insulation colors are available on request.

hulk packing

About Hulk Electric

THE FACTORY
BEHIND EVERY METER

Founded in 2007 in Foshan, Guangdong, Hulk Electric has grown from a regional producer into a globally recognised manufacturer of customised industrial cable solutions. Our 10,000㎡ facility runs on Toyota Production System lean principles, operated by 150+ skilled professionals producing over 300,000 metres every month.

Every cable you see on this page — including the HK-TRVV series — is engineered, extruded, tested, and shipped from that single facility. No trading company sits between you and the extrusion line.

20+Years Manufacturing
30+Countries Served
10K㎡Factory Floor
35+Certifications
01

Source Factory

Direct manufacturer — no middlemen, no markups. You deal with the engineers who run the line.

02

Deep Customization

Conductor, shielding, jacket compound, colour coding, certification — built to your exact spec.

03

7-Day Sampling

Rapid samples for new specifications. 15-day lead time on standard production orders.

04

Global Compliance

35+ certifications covering UL, CE, TÜV, IEC, RoHS and REACH for every major market.

Common Questions

BEFORE YOU ORDER

For stocked configurations listed in the ordering table, MOQ is 100 metres per specification. Custom configurations — non-standard core counts, jacket colours, or special compounds — carry a 500 metre MOQ. Samples of 5–10 metres are available free of charge for qualification testing.

Use shielded (P or PP suffix) whenever the cable runs alongside servo drives, VFDs, or inverters, or when carrying encoder, sensor, or analogue signals. Unshielded is suitable for pure power distribution and simple on/off control lines. If in doubt, our engineering team can review your cabinet layout and advise — this is included with any quotation.

Yes. Send us the existing part number or a sample and we will produce a cross-reference specification with matching electrical, mechanical, and dimensional characteristics. Most cross-references are turned around within 3 working days, with a physical sample following within 7 days.

Standard shipments include the CE Declaration of Conformity, RoHS and REACH statements, and the batch test report. UL Recognition (UL 2464 / UL 20549) is available on request for North American projects — specify this at the quotation stage as it affects the material specification.

Standard configurations ship in 15 working days from order confirmation. Custom-engineered specifications typically require 20–25 working days, depending on compound availability. Rapid sampling for new specifications is 7 days. We will confirm the exact date in writing with your order acknowledgement.

Get a Quotation

SEND US YOUR
SPECIFICATION

Tell us your core count, cross-section, and application — our engineering team will confirm the right configuration and send pricing within one working day.

Reply within 1 working day
Free samples for qualification
Cross-reference from any brand
Direct factory pricing — no middlemen

Your information is used only to prepare your quotation and is never shared with third parties.

Scroll to Top